5-54
E1-30
E1-31
E1-32
E1-40
CCD output
Exposure lamp (not turned on)
Exposure lamp (not turned off)
Optics fan motor (1) rotation
(1) CCD PCB connector is shorted or broken.
(2) CCD PCB is defective.
(3) LVPS connector is shorted or broken.
(4) LVPS is defective.
(5) CPU PCB connector (
CN209
/
210
) is
shorted or broken. (FP-D250/D350)
(6) Image Processing PCB connector (
CN209
/
210
) is shorted or broken. (FP-D450/D600)
(7) CPU is defective.
(8) Image processing PCB is defective.
(FP-D450/D600)
(1) Inverter PCB is defective.
(2) (FP-D250/D350)
CPU PCB connector (
CN17
) is shorted or
broken.
(FP-D450/D600)
CPU PCB connector (
CN17
) is shorted or
broken.
(3) CPU is defective.
(1) Optics mechanism is defective.
(2) CCD PCB connector is shorted or broken.
(3) CCD PCB is defective.
(4) (FP-D250/D350)
CPU PCB connector (
CN17
) is shorted or
broken.
(FP-D450/D600)
CPU PCB connector (
CN17
) is shorted or
broken.
(5) CPU is defective.
(6) Image processing PCB is defective.
(FP-D450/D600)
(1) Fan motor connector is shorted or broken.
(2) Fan motor is defective.
(3) LVPS connector is shorted or broken.
(4) LVPS is defective.
(5) (FP-D250/D350)
CPU PCB connector (
CN17
) is shorted or
broken.
(FP-D450/D600)
CPU PCB connector (
CN17
) is shorted or
broken.
(6) CPU is defective.