6-6
Location
Shipping material/Procedure
Check
FP-D250/D350/D350H:
Turn the power switch ON
FP-D450/D600:
(1) Open the front door.
(2) Turn the power switch ON then
close the front door.
(3) Turn the operation switch ON.
8
(a)
8
(b)
7
TDC adjustment
(1) Press the “User Preset”, “Ledger/
A3 of Original Size” and “3” keys
simultaneously to enter the service
mode.
(2) Press the “8” key to enter the F8
mode.
(3) Press the Start key.
(4) Press the “0”, “9” keys to enter the
F8 mode code “09”
.
(5) Press the Start key for automatic
TDC sensor gain adjustment.
(Wait approximately 2 minutes until
the adjustment cycle stops.)
(6) Write the contents of
F6-21
and
26
on the memory sheet.
Black density sensor output gain
adjustment
(1) Press the “1” and “4” to enter the
F8 mode code “14”
.
(2) Press the “Start” key for automatic
black density sensor output gain
adjustment.
(3) Write the content of
F6-65
on the
memory sheet.
(4) Press the “User Preset” and
“Clear” keys simultaneously to exit
the F mode.