3-48
6. Laser power (PWM circuit) adjustment
Note : This adjustment is required only when the Laser unit has been replaced.
Location
procedure
(-5)
(0)
(+5)
1)Place Ledger/A3 size paper in the
sheet bypass tray.
2)Enter the service mode and select
mode " 8 ".
3)Select
F8-18
and press the Start key
to make a test print.
4)Count the number of gray steps which
are visible in the
F6-39
mode.
Example :
As four gray steps can be seen in the
figure in the left, input '+2' in the
F6-
39
.
No. of
gray scale
1
2
3
4
5
6
7
8
9
10
11
Value
in
F6-39
+5
+4
+3
+2
+1
0
-1
-2
-3
-4
-5
Test print