3-31
Preventive
Maintenance
1)
Removal of exposure lamp
(1)Enter the service mode.
(2)Perform
F8-00
(3)Remove top right cover. (2 screws)
1
(4)Remove two screws on the original guide
plate.
Note: When the conductive platen glass
is installed, the grounding plate
screw must also be removed.
(5)Remove platen glass with original guide
plate.
(1)Remove lamp stoppers (front/rear)
Note: A small flat blade screwdriver must be
used to remove the lamp holder spring
plates.
2
(1)Open the inverter case (2 screws).
(2)Disconnect the exposure lamp connector.
(3)Remove the exposure lamp connector
bracket (1 screw).
(4)Remove the exposure lamp bracket.
(5)Remove the exposure lamp.
3
3
3
4
4
1
1
Содержание FP-D250