Installing the Central Office Terminal Equipment
47
Connect the Subscriber Lines
Connect the subscriber circuits to the subscriber terminations:
1
Refer to Table 14 to connect the CO switch subscriber lines to P1 using a 25-pair Amphenol
cable for system 1.
2
Repeat step 1 for each system installed, using the adapter cables on P2 for system 2, P3 for
system 3, and P4 for system 4.
Table 14. Systems 1 through 4 Subscriber Terminations
Channel Unit
Circuit
Conn Pn* Tip
Conn Pn* Ring
Tip
Ring
1
26
1
WH/BL
BL/WH
2
27
2
WH/OR
OR/WH
3
28
3
WH/GN
GN/WH
1
4
29
4
WH/BN
BN/WH
5
30
5
WH/SL
SL/WH
6
31
6
RD/BL
BL/RD
7
32
7
RD/OR
OR/RD
8
33
8
RD/GN
GN/RD
1
34
9
RD/BN
BN/RD
2
35
10
RD/SL
SL/RD
3
36
11
BK/BL
BL/BK
2
4
37
12
BK/OR
OR/BK
5
38
13
BK/GN
GN/BK
6
39
14
BK/BN
BN/BK
7
40
15
BK/SL
SL/BK
8
41
16
YL/BL
BL/YL
1
42
17
YL/OR
OR/YL
2
43
18
YL/GN
GN/YL
3
44
19
YL/BN
BN/YL
3
4
45
20
YL/SL
SL/YL
5
46
21
VI/BL
BL/VI
6
47
22
VI/OR
OR/VI
7
48
23
VI/GN
GN/VI
8
49
24
VI/BN
BN/VI
BYPASS
50
25
VI/SL
SL/VI
*
Where n is 1 on System 1, 2 on System 2, 3 on System 3, and 4 on System 4.
Содержание PG-Flex
Страница 10: ...PG Flex System Overview 2 Figure 1 Typical PG Flex Configuration 23 Shelf shown ...
Страница 24: ...PG Flex System Overview 16 ...
Страница 44: ...Installing PG Flex System Hardware 36 Figure 16 Line Unit and Channel Unit Installation Locations ...
Страница 52: ...Installing PG Flex System Hardware 44 Figure 21 Connecting the Metallic Bypass Pair ...
Страница 62: ...Installing PG Flex System Hardware 54 ...
Страница 66: ...Terminal Management 58 Figure 28 Connecting an ASCII Terminal to a Line Unit ...
Страница 104: ...Performance Monitoring 96 ...
Страница 120: ...Troubleshooting 112 ...
Страница 158: ...Screen Menus and Definitions A 36 ...
Страница 162: ...Acronyms and Glossary Glossary 4 ...
Страница 167: ......
Страница 168: ......