Alarm History
93
2
Type
and press
at the Main Menu. The Alarm History menu displays:
Table 28 lists the span alarm conditions, listed under the “Type” heading, in the above screen.
Table 28. Span Alarm History Conditions
Status
Description
HDSL1 UAS
The number of seconds (unavailable seconds) the
HDSL1 loop was out of synchronization.
HDSL2 UAS
The number of seconds (unavailable seconds) the
HDSL2 loop was out of synchronization.
HDSL1 MARGIN
Indicates the excess signal to noise ratio, at either the
COT or RT, relative to a 10
-7
Bit Error Rate. The
normal range of a typical margin is from 22 to 6 dB.
C
Enter
01-SEP-97 PAIRGAIN TECHNOLOGIES INC., PG-FLEX TERMINAL 00:01:56
SYSTEM ID: PairGain PG-Flex System SYSTEM: 1
SPAN-1 ALARM HISTORY
------------------------------------------------------------------------------
Type First Last Status Current Count
------ -------------- -------------- ---------- ------- -----
HDSL1 UAS JUN 12, 00:00 JUN 12, 00:00 Enabled NONE 1
HDSL2 UAS JUN 12, 00:00 JUN 12, 00:00 Enabled NONE 2
HDSL1 MARGIN JUN 12, 00:00 JUN 12, 00:00 Enabled NONE 1
e(X)it > (S)pan >s
Содержание PG-Flex
Страница 10: ...PG Flex System Overview 2 Figure 1 Typical PG Flex Configuration 23 Shelf shown ...
Страница 24: ...PG Flex System Overview 16 ...
Страница 44: ...Installing PG Flex System Hardware 36 Figure 16 Line Unit and Channel Unit Installation Locations ...
Страница 52: ...Installing PG Flex System Hardware 44 Figure 21 Connecting the Metallic Bypass Pair ...
Страница 62: ...Installing PG Flex System Hardware 54 ...
Страница 66: ...Terminal Management 58 Figure 28 Connecting an ASCII Terminal to a Line Unit ...
Страница 104: ...Performance Monitoring 96 ...
Страница 120: ...Troubleshooting 112 ...
Страница 158: ...Screen Menus and Definitions A 36 ...
Страница 162: ...Acronyms and Glossary Glossary 4 ...
Страница 167: ......
Страница 168: ......