Channel Configuration
Each POTS and ISDN circuit installed in a PG-Flex system can be individually enabled or disabled
from the Channel Configuration menu.
1
From the Setup Menu, type
and press
. The Channel Configuration menu is
displayed on your terminal screen:
2
Type
(disable) or
(enable) and press
. You get a prompt.
3
At the prompt, type the numbers for the channel unit and channel you want to disable/enable
specified
x,x
(channel unit, channel) and press
.
There are 24 time slots available. Enable is the default for the channels. Disable channels only
when the time slots are required by another channel unit. ON indicates that the channel is
enabled with a time slot. OFF means that the channel is enabled but does not have the necessary
time slot(s) assigned.
Table 22. Channel Configuration Options
Parameter
Default Value
Function
Channel
Configuration
Enabled
Each channel is individually enabled or disabled. This configuration is
stored in both the COLU and the CO channel card. If any one card
(COLU, RTLU, COCU or RTCU) is removed, replaced, or reinserted,
the Channel Configuration is automatically preserved. Can be set to the
following parameters:
•
DISABLED: The selected channel is disabled.
•
ENABLED: The selected channel is enabled.
C
Enter
06-FEB-96 PAIRGAIN TECHNOLOGIES INC., PG-FLEX TERMINAL 03:41:20
SYSTEM ID: PG-Flex 24 Channel System SYSTEM: 2
CHANNEL CONFIGURATION
------------------------------------------------------------------------------
CU1
CU2
CU3
Channel
COT
(POTS8)
(POTS8)
(ISDN4)
RT
(POTS8)
(POTS8)
(ISDN4)
(---)
------------------------------------------------------------------------------
1
ON
ON
ON
2
ON
ON
OFF
3
ON
ON
DISABLED
4
ON
ON
DISABLED
5
ON
ON
-
6
ON
ON
-
7
ON
ON
-
8
ON
ON
-
2 Time-Slots Available
D)isable Channel E)nable Channel
CTRL-X) Main Menu e(X)it
[COT] ENTER COMMAND> D
D
E
Enter
Enter
Содержание PG-Flex
Страница 10: ...PG Flex System Overview 2 Figure 1 Typical PG Flex Configuration 23 Shelf shown ...
Страница 24: ...PG Flex System Overview 16 ...
Страница 44: ...Installing PG Flex System Hardware 36 Figure 16 Line Unit and Channel Unit Installation Locations ...
Страница 52: ...Installing PG Flex System Hardware 44 Figure 21 Connecting the Metallic Bypass Pair ...
Страница 62: ...Installing PG Flex System Hardware 54 ...
Страница 66: ...Terminal Management 58 Figure 28 Connecting an ASCII Terminal to a Line Unit ...
Страница 104: ...Performance Monitoring 96 ...
Страница 120: ...Troubleshooting 112 ...
Страница 158: ...Screen Menus and Definitions A 36 ...
Страница 162: ...Acronyms and Glossary Glossary 4 ...
Страница 167: ......
Страница 168: ......