Remote Terminal Equipment
9
RT Line Units
The RT line unit includes the HDSL transceivers and converts the line power from the COT into
the voltages required by the remote terminal electronics. Regardless of the number of channels
being transported by PG-Flex, two copper pairs are required between the CO and the RT to support
the HDSL transport and provide power to the RT. As shown in Figure 6, both pairs are used for
simplexing the power between the COT and RT.
Figure 6. Connections Between the COT and RT
For subscriber drop testing, a third copper pair is required between the COT and RT to provide a
metallic path between the selected subscriber pair and the Central Office test equipment.