Troubleshooting Using Standard Test Equipment
111
HDSL Transmission Distance
The distance limitation for HDSL transmission is based on a maximum signal attenuation of 35 dB
at 196 kHz. Since signal attenuation decreases as cable size increases, the larger the gauge
(i.e., 19 AWG vs. 26 AWG), the greater the distance between the COT and the RT. Table 35
identifies these distances (at a cable temperature of 68°F).
Table 35. 12/24 Channel HDSL Transmission Distance
Gauge
Loop Length
DC Resistance
19 AWG
0.9 mm
22.8 kft
7.0 km
367
Ω
22 AWG
0.6 mm
16.1 kft
4.9 km
521
Ω
24 AWG
0.5 mm
12.3 kft
3.7 km
638
Ω
26 AWG
0.4 mm
9.0 kft
2.7 km
750
Ω