STARTER DELAY
- This is the amount of time between when the module activates the
Ignition circuit before it will engage the starter solenoid. You have the option of selecting
0, 3, or 7 seconds. This is useful for vehicles that need to prime the fuel system and
build fuel pressure before startup or even for diesel applications that need glow plugs
heated before start up. Starter Delay is Feature #1 the default setting is 0 seconds.
DOOR LOCK OUTPUT
- This feature will allow you to make to outputs for the door locks
single or double pulse. Some newer vehicles require double pulses to unlock all doors
or require a double pulse in order to activate the body control module before the door
will unlock. Programming the module for double pulse even though your vehicle does
not require it will have no ill effects on your components, it will simply activate the relay
twice. Door Lock Output is feature #2, the default setting is single pulse.
TRUNK/HATCH RELEASE
- This feature will allow you to choose between a
momentary or latched activation of the accessory relay. A momentary activation will
simply close the relay to apply power for a very short amount of time, about 1 second.
This would be used to activate simple locking solenoids that simply need to be released.
A latched activation will keep power coming out of the relay until the system is either
deactivated or until the stainless button is pushed. Trunk/Hatch release is feature #3,
the default is momentary.
START BUTTON LED
- This feature will allow you to change the way the stainless push
button appears when the module is armed. You can change between OFF and
FLASHING. Flashing will cause the LED to flash, or blink, when the system is armed.
This flashing will be a visual sign that the module has not recognized your key fob,
therefore, will not allow vehicle startup. This also mimics the blinking lights found on
many anti-theft/alarm systems, a visual sign to a would be thief that your vehicle is
protected. This Start Button LED flash is feature #4, the default setting is OFF.
FEATURE
POSITION 1
POSITION 2
POSITION 3
#1 STARTER DELAY
0 SECONDS
3 SECONDS
7 SECONDS
#2 DOOR LOCK OUTPUTS
SINGLE PULSE
DOUBLE PULSE
not available
#3 TRUNK/HATCH RELEASE
MOMENTARY
LATCHED
not available
#4 START BUTTON LED
OFF WHEN
INACTIVE
FLASHING WHEN
INACTIVE
not available
Changing modes
Read these steps from start to finish before attempting to change any settings in
the module. To enter into the Programmable Feature Mode of the module follow these
simple steps:
Put the system in Accessory mode
.
This is done by pressing the stainless push
button one time without applying the brake.
Содержание PHANTOM KEY Series
Страница 1: ...Phantom Key Push Button Ignition System Instruction Part 90577 For Installing Part s 55000 55001 55002...
Страница 15: ...15...
Страница 20: ...20...