Ossila Slot-Die Coater
User Manual
Ossila.com
38
Ossila Limited © 2019
Links to further helpful resources for coating and troubleshooting can be found on
Ossila’s website,
including:
•
Quickstart Video guide (
https://www.ossila.com/products/slot-die-coater)
•
Slot-Die Coating: Theory, Design & Applications Article (
https://www.ossila.com/pages/slot-
die-coating-theory
)
•
Slot-Die Coating: Guide to Troubleshooting Defects (
https://www.ossila.com/pages/slot-die-
coating-defect-troubleshooting
)
12.
Appendix
12.1
Minimum and Maximum Flow Rates
Table 12.1
Minimum and maximum flow rates possible with different sized syringes
Syringe Volume
Syringe Diameter
Minimum Flow Rate
Maximum Flow Rate
1 mL
4.69 mm
0.021 µL/s
86.4 µL/s
2 mL
9.65 mm
0.087 µL/s
365.7 µL/s
5 mL
12.45 mm
0.145 µL/s
608.7 µL/s
10 mL
15.90 mm
0.236 µL/s
1 mL/s
20 mL
20.05 mm
0.376 µL/s
1 mL/s
50 mL
29.60 mm
0.797 µL/s
1 mL/s