![Orientalmotor AZD-K Скачать руководство пользователя страница 18](http://html1.mh-extra.com/html/orientalmotor/azd-k/azd-k_operating-manual_1651207018.webp)
Connection
▌
18
Use input signals at 24 VDC.
Use output signals at 12 to 24 VDC, 10 mA or less. If the current exceeds 10 mA, connect an
external resistor R0 so that the current becomes 10 mA or less.
The saturated voltage of the output signal is 3 VDC maximum.
Pulse input type with RS-485 communication interface, pulse input type
The pin No.1, No.2, No.13, and No.14 are only available to the pulse input. Other functions cannot be assigned.
When pulse input is of line driver type
0 V
CW+ [PLS+]
CW- [PLS-]
CCW+ [DIR+]
CCW- [DIR-]
270 Ω
270 Ω
5.6 kΩ
270 Ω
270 Ω
5.6 kΩ
470 Ω
470 Ω
Driver
Controller
1
13
2
14
Twisted pair cable
When pulse input is of open-collector type (When using the voltage of pulse input signals at 5 VDC)
5 VDC
0 V
CW+ [PLS+]
CW- [PLS-]
CCW+ [DIR+]
CCW- [DIR-]
270 Ω
270 Ω
5.6 kΩ
270 Ω
270 Ω
5.6 kΩ
470 Ω
470 Ω
Driver
Controller
1
13
2
14
Twisted pair cable
When pulse input is of open-collector type (When using the voltage of pulse input signals at 24 VDC)
R1
1.2 kΩ to 2.2 kΩ
0.5 W or more
1.2 kΩ to 2.2 kΩ
0.5 W or more
R1
24 VDC
0 V
CW+ [PLS+]
CW- [PLS-]
CCW+ [DIR+]
CCW- [DIR-]
270 Ω
270 Ω
5.6 kΩ
270 Ω
270 Ω
5.6 kΩ
470 Ω
470 Ω
Driver
Controller
1
13
2
14
Twisted pair cable
Use the CW [PLS] input and CCW [DIR] input at 5 VDC to 24 VDC. When using signals at 24 VDC,
connect an external resistor R1 (1.2 kΩ to 2.2 kΩ, 0.5 W or more). When using signals at 5 VDC, apply
the voltage directly.