Preparation
11
▐
Pulse input type
Name
Display
Description
1
POWER/ALARM LED
(Green/Red)
POWER/ALARM
This LED is lit in green while the power is input.
If an alarm (protective function) generates, the LED will blink in red.
If an information generates, the LED will blink in red and green
simultaneously. (Red and green colors may overlap and it may be visible to
orange.)
2
READY LED (Green)
READY
This LED is lit while the READY output is ON. It is not lit when the READY
output is OFF.
5
HOME PRESET
switch
HOME PRESET
This switch is used to set the starting position (home position) when
performing positioning operation.
9
Function setting
switch
SW1
No.1: This switch is used to set the resolution per revolution of the motor
output shaft.
Factory setting: OFF (1000 p/r)
No.2: This switch is used to toggle between the 1-pulse input mode and
2-pulse input mode.
The factory setting of the pulse-input mode depends on the destination
country.
No.3, No.4: Not used.
10
Current setting
switch
CURRENT
This switch is used to set the base current rate for the operating current and
standstill current.
Factory setting: F
11
Command fi lter
setting switch
FIL
This switch adjusts the motor response.
Factory setting: 1