8 Error handling
-
68
-
•
No. of ALARM LED blinks: 7
Condition Display
Opera
tion
Causes Action
ACL
HOME offset
error
Err6A HOME
Offset Error
2
The LS signal was
detected during home
offset operation.
Reset the alarm, and then check the
home offset value.
Valid
Abnormal
operation data
Err70 Data Out of
Range
2
•
Five or more operation
data have been linked.
•
Operation data of
different directions have
been linked.
•
Data No. 1 is not set in
sequence-forward
positioning operation.
•
The operating speed for
push-motion operation
exceeds 6 mm/s
(0.24 in/s).
Check the operation data after
resetting the alarm.
Valid
•
No. of ALARM LED blinks: 8
Condition Display
Opera
tion
Causes Action
ACL
Sensor error
Err28 Sensor
Error
1 Abnormality
was
detected
in the rotor position
detection sensor in the
motor while the motor was
operating.
Turn off the power and check the
motor cable and its connection to the
controller, and then reconnect the
power.
Invalid
Motorized
actuator
communication
error
Err2A ActuatorNo
Connect
1
A communication error with
the controller key occurred.
Turn off the power, check the
connection with the controller
key/controller, and then reconnect the
power.
Invalid
Sensor error
Err42 Sensor
Error
1
The motor cable was not
connected when the power
was input.
Turn off the power and check the
motor cable and its connection to the
controller, and then reconnect the
power. Be sure to perform
return-to-home operation after the
power is turned on.
Invalid
Rotation at
initialization
Err43 Sensor
Error
1
Initialization failed because
the motor was rotating
when the power was
turned on.
Check the load. An external load or a
load exceeding the specified value has
been applied to the moving part of the
motorized actuator when the power
was turned on.
Invalid
Nonvolatile
memory error
Err44 Memory
Error
1
Data stored in the
controller key was
damaged.
Turn off the power and check the
controller key and its connection to the
controller, and then reconnect the
power.
Invalid
Motorized
actuator
combination error
Err45 Actuator
Mismatch
1
The supply voltage
specification of the
controller is different from
the supply voltage
specification stored in the
controller key’s motorized
actuator information.
Turn off the power, check the
connection with the controller
key/controller, and then reconnect the
power.
Invalid