5 Timing charts
-
36
-
Deceleration stop
+ Electromagnetic
brake actuation
STOP input
START input
MOVE output
END output
Motor operation
Stop
Motor excitation
Electromagnetic
brake
Motor is excited
Release
Hold
Release
100 ms or less
6 ms or less
MOVE output OFF, or
elapse of at least 4 ms
200 ms
or more
150 ms or less
25 ms or less
OFF
ON
OFF
ON
OFF
ON
OFF
ON
∗
Delay when the motor
is not excited = 200 ms
Note
The time after the STOP input turns ON until the motor stops varies depending on the
load and operating speed (the section indicated by
∗
in the timing chart).
5.6 Stopping the motor excitation
FREE Input
●
C
●
D
When the STOP or C.OFF
is ON
25 ms or less
150 ms or less
FREE input
Hold
Release
Hold
Motor excitation
Electromagnetic
brake
motor is not excited
OFF
ON
When the STOP or C.OFF
is OFF
100 ms or less
6 ms or less
FREE input
OFF
ON
Motor excitation
Electromagnetic
brake
Release
Motor is excited
motor is
not excited
C.OFF Input
●
D
C.OFF input
Motor excitation
FP or RP input
100 ms or less
100 ms or more
Delay when the motor
is not excited = 200 ms
Motor is excited
Electromagnetic
brake
Release
Hold
Release
150 ms or less
50 ms or less
OFF
ON