3 Connection
-
12
-
3.2 Connecting to the power supply
The power supply is used to drive the motor.
After connection, be sure to install the terminal cover.
Controller model
Power supply specification
Applicable lead wire
Tightening torque
ESMC-K
24 VDC 4.0 A
∗
1
ESMC-A
Single phase 100-115 V 50/60 Hz 6.4 A
∗
2
ESMC-C
Single phase 200-230 V 50/60 Hz 3.9 A
∗
3
Solid wire: AWG16 (Ø1.6 mm)
Stranded wire: AWG16 (1.25 mm
2
)
0.8 to 1.0 N·m
(113.6 to 142 oz-in)
∗1
The maximum current varies depending on the motorized actuator connected to the controller.
SPRM4
: 1.0
A
EZSM3, EZSM4, SPRM6
: 1.7
A
EZSM6, SPFM6, SPFM8, SPVM6, SPRM8
: 4.0
A
∗2
The maximum current varies depending on the motorized actuator connected to the controller.
EZSM3, EZSM4, SPRM6
: 3.0
A
EZSM6, SPFM6, SPFM8, SPVM6, SPRM8
: 5.0
A
SPVM8, PWAM8
: 6.0
A
PWAM6
: 6.4
A
∗3
The maximum current varies depending on the motorized actuator connected to the controller.
EZSM3, EZSM4, SPRM6
: 2.1
A
EZSM6, SPFM6, SPFM8, SPVM6, SPRM8
: 3.0
A
SPVM8, PWAM8
: 3.5
A
PWAM6
: 3.9
A
24 VDC
•
ESMC-K
•
ESMC-A
,
ESMC-C
GND
FG
L
N
FG
•
Applicable crimp terminal
Insulated round crimp terminal
Ø3.2 mm (0.13 in.) or more
6.2 mm (0.24 in.)
or less
3.3 Connecting to the control signal power supply
Applicable wire
Solid wire: AWG16 (Ø1.6 mm)
Stranded wire: AWG16 (1.25 mm
2
)
Standard strip length
11 mm (0.43 in.)
GND
1.
Press the button next to the terminal.
Applicable tool: Flat-head screwdriver
[shaft diameter: Ø3 mm (Ø0.12 in.), blade tip width: 2.6 mm (0.10 in.)]
2.
Insert the wire.
24 VDC input (Max. 1 A)
3.4 Grounding the controller
Applicable wire
Solid wire: AWG16 (Ø1.6 mm)
Stranded wire: AWG16 (1.25 mm
2
)
Protective earth terminal
M4
Tightening torque :1.0 to 1.3 N·m (142 to 185 oz-in)
The
ESMC-K
has no protective ground terminal.
Ø4.1 mm (Ø0.16 in.)
or more
9.5 mm (0.37in.)
or less
•
Applicable crimp terminal Insulated round crimp terminal
㪧㪜