8 Error handling
-
67
-
•
No. of ALARM LED blinks: 7
Condition Display
Opera
tion
Causes Action
ACL
Insufficient ABS
battery voltage
Err27 Low Battery
Error
2
The ABS backup battery
voltage dropped to, or
below, the specified value.
(If the absolute position
has been lost, then alarm
code 33 “Absolute position
loss error”, is displayed
instead.)
•
Charge the battery.
•
After resetting the alarm, perform a
return-to-home operation.
•
The battery may have reached its
useful life. Please call our Technical
Support Line or contact your nearest
Oriental Motor branch or sales
office.
Valid
Absolute position
loss
Err33 Position
Lost
2
•
Power was turned on for
the first time after the
battery was connected.
•
Battery is not connected
or has been consumed.
•
The motor cable was
disconnected when the
main power was OFF.
•
The battery cable
became open or a fuse
was blown.
•
Reset the alarm, and then perform
return-to-home operation.
•
If the alarm still generates after
charging the battery, a consumed
battery, open cable or blown fuse
may be the cause. Please call our
Technical Support Line or contact
your nearest Oriental Motor branch
or sales office.
Valid
LS logic error
Err60 LS Logic
Error
2 The
−
LS and +LS sensors
were detected in the
sensor-enable mode.
Reset the alarm, and then check the
logic of the installed sensors and the
logic setting in the LS logic setting
parameter.
Valid
LS reverse
connection error
Err61 LS Rev
Error
2
The LS sensor opposite to
the operating direction was
detected during a
return-to-home operation.
(2-sensor mode, 3-sensor
mode)
Reset the alarm, and then check the
+LS and
−
LS wiring.
Valid
Return-to-home
error
Err62 Home
SequenceError
2
A return-to-home operation
did not complete normally.
•
An unanticipated load may have
been applied during the
return-to-home operation. Check the
load.
•
If the installation positions of +LS,
−
LS and HOMELS are close to one
another, the return-to-home
sequence may not end properly,
depending on the starting direction
of return-to-home operation. Review
the sensor installation positions and
the starting direction of
return-to-home operation.
•
Return-to-home operation may have
been performed in a condition where
both +LS and
−
LS were detected.
Check the logic of the installed
sensors and the logic setting in the
LS logic setting parameter.
Valid
HOMELS
non-detection
error
Err63 NoHome
Detect
2
The HOMELS signal is not
output at a position
bLS and
−
LS
during HOME operation
(3-sensor mode).
Set a HOME sensor between the limit
sensors (+LS,
−
LS).
Valid
LS detection
error
Err66 LS
Detected
2
The +LS or
−
LS sensor
was detected in the
sensor-enable mode.
After resetting the alarm, pull the
actuator out of the limit sensor via
continuous operation or perform
return-to-home operation.
Valid
Soft limit
detection
Err67 Soft Lim
Detected
2
The moving part of the
motorized actuator reached
a soft limit.
After resetting the alarm, pull the
actuator out of the soft limit via
continuous operation or perform
return-to-home operation.
Valid