5 Timing charts
-
35
-
5.5 Stopping
function
●
C
Operation stop using the STOP input is controlled via the CPU.
Immediate stop
STOP input
START input
MOVE output
END output
Motor operation
Stop
Motor is excited
1 ms or more
ON
OFF
ON
OFF
ON
OFF
ON
OFF
∗
Motor excitation
MOVE output OFF, or elapse of at least 4 ms
Deceleration stop
STOP input
START input
MOVE output
END output
Motor operation
Stop
Motor is excited
6 ms or less
1 ms or more
ON
OFF
ON
OFF
ON
OFF
ON
OFF
MOVE output OFF, or
elapse of at least 4 ms
∗
Motor excitation
Immediate stop
+ Electromagnetic
brake actuation
STOP input
START input
MOVE output
END output
Stop
Release
Hold
Release
100 ms or less
200 ms
or more
150 ms or less
25 ms or less
ON
OFF
ON
OFF
ON
OFF
ON
OFF
∗
Motor operation
Motor excitation
Electromagnetic
brake
Motor is excited
MOVE output OFF, or
elapse of at least 4 ms
Delay when the motor
is not excited = 200 ms
Note
The time after the STOP input turns ON until the motor stops varies depending on the
load and operating speed (the section indicated by
∗
in the timing chart).