Replace the Battery
c.
Check the NTP policy for the
/SP/clock
.
->
show /SP/clock usentpserver
Properties:
usentpserver = enabled
d.
If enabled, set the property to
disabled
.
->
set /SP/clock usentpserver=disabled
2.
Replace the battery.
Replacing the battery is a cold-service procedure. The server must be
and power cables disconnected before performing this procedure.
a.
Prepare the server for service
b.
CM0/MR0, CM0/MR2 and CM0/MR3.
c.
Remove the old battery.
Gently push the battery toward the memory risers to release it from the retention clip.
112
SPARC T8-2 Server Service Manual • June 2019
Содержание SPARC T8-2
Страница 1: ...SPARC T8 2 Server Service Manual Part No E80511 04 June 2019 ...
Страница 2: ......
Страница 10: ...10 SPARC T8 2 Server Service Manual June 2019 ...
Страница 12: ...12 SPARC T8 2 Server Service Manual June 2019 ...
Страница 24: ...Server Block Diagram 24 SPARC T8 2 Server Service Manual June 2019 ...
Страница 26: ...26 SPARC T8 2 Server Service Manual June 2019 ...
Страница 62: ...62 SPARC T8 2 Server Service Manual June 2019 ...
Страница 82: ...82 SPARC T8 2 Server Service Manual June 2019 ...
Страница 110: ...110 SPARC T8 2 Server Service Manual June 2019 ...
Страница 114: ...114 SPARC T8 2 Server Service Manual June 2019 ...
Страница 128: ...128 SPARC T8 2 Server Service Manual June 2019 ...
Страница 135: ...Verify the SPM Related Information Oracle ILOM documentation Install the SPM on page 131 Servicing the SPM 135 ...
Страница 136: ...136 SPARC T8 2 Server Service Manual June 2019 ...
Страница 146: ...146 SPARC T8 2 Server Service Manual June 2019 ...
Страница 164: ...164 SPARC T8 2 Server Service Manual June 2019 ...
Страница 170: ...170 SPARC T8 2 Server Service Manual June 2019 ...
Страница 176: ...176 SPARC T8 2 Server Service Manual June 2019 ...
Страница 182: ...182 SPARC T8 2 Server Service Manual June 2019 ...
Страница 188: ...188 SPARC T8 2 Server Service Manual June 2019 ...