RGN-3GSF Release 5.7 User Guide, 3005-9800 REV-11
5
Installing and removing the card and modules
The RGN-3GSF is a single-width card that requires one shelf slot for installation. When the installation
environment requires the card to operate within the normal temperature range (-5°C to 55°C [23°F to
131°F]), the card can be installed in any Optelian mounting platform. When the installation environment
requires the card to operate within the extended temperature range (-40°C to 65°C [-40°F to 149°F]), the
card must be installed in an OMS-2190 mounting platform.
Table 3: Supported shelf type based on operating temperature
Installing the card and SFP modules
1.
Pull firmly on the latches and ensure they are in the open position.
2.
Insert the card into a valid slot, and push gently until the card engages with the backplane:
•
OMS-2190 or OMS-219: slots 2 to 4
•
OMS-7190, OMS-719 or OMS-519: slots 1 to 13
Note:
The card can be installed in a powered shelf.
Shelf type
Normal operating temperature
-5°C to 55°C (23°F to 131°F)
Extended operating temperature
-40°C to 65°C (-40°F to 149°F)
OMS-219
OMS-519
OMS-719
OMS-2190
OMS-7190