RGN-3GSF Release 5.7 User Guide, 3005-9800 REV-11
29
Table 10: RGN-3GSF port alarms .
Error messages
The error message
Operation not available for this SFP
is shown on the faceplate displayed when a mode
setting is not supported by the SFP. For example, if you try to set the transmit mode of an RJ-45 SFP to
DISABLED, the error message is displayed and the mode of the SFP is NOT changed to DISABLED.
Alarm Message
Description
Severity
Corrective Action
All Ports
OK
No alarms are present
N/A
None
SFP_Absent
SFP is missing
Major
Insert SFP
SFPInvalid
A third-party (non-Optelian)
SFP module was inserted in
the port, with the card
configured to block the use of
third-party SFP modules.
Major
Insert a valid Optelian SFP module. Refer to
the Optelian Pluggable Modules Product
Guide (document number 3019-4100).
Reconfigure the card to allow third-party
SFP modules. Refer to “Configure card
advanced parameters” on page 21)
TempFlt
SFP case temperature fault
Major
Decrease ambient temperature or increase
ventilation
Transmit Ports 1, 3, 5, 7
Tx Fault
Tx failure in SFP
Major
Replace the SFP
TxLOL
Loss of lock
Major
Check for a valid input signal at the
appropriate receive port as follows:
Port 1
• Port P2 for Regen configuration
• Port P4 for Transponder configuration
Port 3
• Port P4 for Regen configuration
• Port P2 for Transponder configuration
Port 5
• Port P6 for Regen configuration
• Port P8 for Transponder configuration
Port 7
• Port P8 for Regen configuration
• Port P6 for Transponder configuration
Receive Ports 2, 4, 6, 8
RxLOS
Loss of signal
Major
Check port input power