RGN-3GSF Release 5.7 User Guide, 3005-9800 REV-11
21
Table 5: RGN-3GSF Operation parameters
Configure card advanced parameters
CAUTION:
Modifying
Advanced
settings should only be done under the guidance of Optelian Support
personnel. As such, some parameters are not explained in this guide.
1.
In the shelf view of the ONM or OSM, double-click the card, or right-click the card and choose
Card
Config
from the drop-down menu.
2.
In the Configuration for Device screen, click the RGN-3GSF button, then click the
Advanced
tab.
3.
Click
OK
in the Warning Message dialog box.
Parameter
Value
Default
Description
SFP1-SFP2 Group
Connection Mode
SFP1 Absent, SFP2 Absent
SFP1 Absent, SFP2 Regen
SFP1 Regen, SFP2 Absent
SFP1 Regen, SFP2 Regen
Bi-Directional
Transponder
SFP1 Absent, SFP2 Absent
SFP1 Absent, SFP2 Absent:
Both SFPs are disabled.
SFP1 Absent, SFP2 Regen:
SFP1 is disabled and SFP2 is
available as a regenerator.
SFP1 Regen, SFP2 Absent:
SFP1 is available as a
regenerator and SFP2 is
disabled.
SFP1 Regen, SFP2 Regen: Both
SFPs are available as a
regenerator.
Bi-Directional Transponder:
The SFPs are paired to operate
as a 4-port bidirectional signal
regenerator.
SFP3-SFP4 Group
Connection Mode
SFP3 Absent, SFP4 Absent
SFP3 Absent, SFP4 Regen
SFP3 Regen, SFP4 Absent
SFP3 Regen, SFP4 Regen
Bi-Directional
Transponder
SFP3 Absent, SFP4 Absent
SFP3 Absent, SFP4 Absent:
Both SFPs are disabled.
SFP3 Absent, SFP4 Regen:
SFP3 is disabled and SFP4 is
available as a regenerator.
SFP3 Regen, SFP4 Absent:
SFP3 is available as a
regenerator nand SFP4 is
disabled.
SFP3 Regen, SFP4 Regen: Both
SFPs are available as a
regenerator.
Bi-Directional Transponder:
The SFPs are paired to operate
as a 4-port bidirectional signal
regenerator.