Table 7:  RGN-3GSF SFP protection parameters

Parameter

Value

Default

Description

Protection Mode

On, Off

Off

Enables (On) or disables (Off) optical 
protection switching 

PPM Slot Number

1 to 12

0 (the address has not 
been assigned)

The slot number of a PPM (Path 
Protection Module) that is protecting the 
corresponding interface. The PPM must 
be installed in the same shelf as the 
RGN-3GSF.

Содержание RGN-3GSF

Страница 1: ...U S E R G U I D E RELEASE 5 7 RGN 3GSF User Guide 2 7 Gb s multi protocol dual transponder card...

Страница 2: ...nd contact the supplier for confirmation Optelian assumes no responsibility or liability for incorrect or incomplete information provided about non Optelian products Optelian products are intended for...

Страница 3: ...ay and control keys 8 Display menu hierarchy 10 Viewing card information 11 Viewing the port configuration 11 Configuring the SFPs and ports 12 Configuration example 13 Configuring the RGN 3GSF using...

Страница 4: ...ii Table of contents RGN 3GSF Release 5 7 User Guide 3005 9800 REV 11...

Страница 5: ...and status and configuration access via a faceplate graphic display touch pad controls and LEDs As part of the Optelian suite of products the card mounts in any active shelf and can be configured and...

Страница 6: ...bandwidth provisioning reach extension and interface conversion applications SFPs can be configured as separate regenerators where each SFP functions as an independent 2 port signal regenerator or pai...

Страница 7: ...the Optelian Pluggable Modules Product Guide 3019 4100 Table 2 Ordering information Parameter Specification Data rate 100 Mb s to 2 7 Gb s Jitter generation transfer tolerance Telcordia GR 253 Eye ma...

Страница 8: ...follow the safety precautions described in this section Always turn off any laser sources before you inspect fiber connectors or optical components Never look into the end of an optical cable fiber o...

Страница 9: ...rature range 40 C to 65 C 40 F to 149 F the card must be installed in an OMS 2190 mounting platform Table 3 Supported shelf type based on operating temperature Installing the card and SFP modules 1 Pu...

Страница 10: ...installation environment requires the card to operate within the extended temperature range 40 C to 65 C 40 F to 149 F the card must be populated with SFP modules that support this temperature range...

Страница 11: ...odule 1 Disconnect all patchcords and remove each SFP as follows a Open the release latch to disconnect the SFP and eject it partially out of the port b Grasp the SFP with your fingers and gently remo...

Страница 12: ...port settings Note Operating the RGN 3GSF in a shelf where a management card is installed is defined as operation in a managed system When operating the RGN 3GSF in a managed system the faceplate disp...

Страница 13: ...scrolls down to the next item in the display Select selects the highlighted item to be the next display To operate any of the keys press the key once If the display is off press any key to activate t...

Страница 14: ...FP Tx P2 SFP Rx P3 SFP Tx P4 SFP Rx P5 SFP Tx P6 SFP Rx P7 SFP Tx P8 SFP Rx SFP ESC SC SEL Card Alarms Part No 1004 2100 card SN 31526 sw Rev 4 1 30 SLOT 12 ESC SC SEL Card Menu Display Alarm Laser Se...

Страница 15: ...onfiguration display examples Figure 9 Viewing port configuration RGN 3GSF ESC SC SEL RGN 3GSF Card P1 SFP Tx P2 SFP Rx P3 SFP Tx P4 SFP Rx P5 SFP Tx P6 SFP Rx P7 SFP Tx P8 SFP Rx SFP ESC SC SEL Card...

Страница 16: ...able 4 SFP and port configuration settings SFP and port parameters Default Setting and Description Connection mode P1P2 P3P4 SFP1 and SFP2 port groups Abs Abs Abs Abs SFP1 and SFP2 are disabled absent...

Страница 17: ...FP Rx P3 SFP Tx P4 SFP Rx P5 SFP Tx P6 SFP Rx P7 SFP Tx P8 SFP Rx SFP ESC SC SEL RGN 3GSF Card P1 SFP Tx P2 SFP Rx P3 SFP Tx P4 SFP Rx P5 SFP Tx P6 SFP Rx P7 SFP Tx P8 SFP Rx SFP ESC SC SEL SFP P1P2 P...

Страница 18: ...rr Conf Reg Reg Change No Yes ESC SC SEL RGN 3GSF Card P1 SFP Tx P2 SFP Rx P3 SFP Tx P4 SFP Rx P5 SFP Tx P6 SFP Rx P7 SFP Tx P8 SFP Rx SFP ESC SC SEL SFP P1P2 P3P4 P5P6 P7P8 ESC SC SEL P5P6 P7P8 Chang...

Страница 19: ...3 SFP Tx P4 SFP Rx P5 SFP Tx P6 SFP Rx P7 SFP Tx P8 SFP Rx SFP ESC SC SEL P1 SFP Tx Alarms Tx Laser Tx Disable Mode Power ESC SC SEL P1 Tx Mode Curr Mode 3R Change No Yes ESC SC SEL P1 Tx Mode Change...

Страница 20: ...P3 SFP Tx P4 SFP Rx P5 SFP Tx P6 SFP Rx P7 SFP Tx P8 SFP Rx SFP ESC SC SEL RGN 3GSF Card P1 SFP Tx P2 SFP Rx P3 SFP Tx P4 SFP Rx P5 SFP Tx P6 SFP Rx P7 SFP Tx P8 SFP Rx SFP ESC SC SEL P1 SFP Tx Alarms...

Страница 21: ...P7 SFP Tx P8 SFP Rx SFP ESC SC SEL P2 SFP Rx Alarms Data Rate BW Limit Power ESC SC SEL P2 SFP Rx Alarms Data Rate BW Limit Power ESC SC SEL RGN 3GSF P2 X P1 P7 P6 P8 P5 ESC SC SEL Repeat the sequence...

Страница 22: ...P Tx P2 SFP Rx P3 SFP Tx P4 SFP Rx P5 SFP Tx P6 SFP Rx P7 SFP Tx P8 SFP Rx SFP ESC SC SEL RGN 3GSF Card P1 SFP Tx P2 SFP Rx P3 SFP Tx P4 SFP Rx P5 SFP Tx P6 SFP Rx P7 SFP Tx P8 SFP Rx SFP ESC SC SEL P...

Страница 23: ...19 Configure card operating parameters on page 20 Configure card advanced parameters on page 21 After completing a configuration setting click on the Apply button to implement the configuration To rev...

Страница 24: ...the shelf view of the ONM or OSM double click the card or right click the card and choose Card Config from the drop down menu 2 In the Configuration for Device screen click the RGN 3GSF button then cl...

Страница 25: ...SFP1 Absent SFP2 Absent SFP1 Absent SFP2 Absent Both SFPs are disabled SFP1 Absent SFP2 Regen SFP1 is disabled and SFP2 is available as a regenerator SFP1 Regen SFP2 Absent SFP1 is available as a reg...

Страница 26: ...s installed b Enabled this allows third party non Optelian SFP modules to be used in the card When set to Enabled the sfpInvalid alarm is not raised when a non Optelian SFP is installed Note When usin...

Страница 27: ...ure SFP operating parameters on page 23 Configure SFP protection parameters on page 24 View SFP advanced parameters on page 26 Configure SFP operating parameters 1 In the shelf view of the ONM or OSM...

Страница 28: ...rt Label 0 to 64 alphanumeric character N A User specified label for the port Transmitter On enabled Off disabled On enabled When enabled the SFP automatically turns on when a valid signal is present...

Страница 29: ...FP protection parameters Parameter Value Default Description Protection Mode On Off Off Enables On or disables Off optical protection switching PPM Slot Number 1 to 12 0 the address has not been assig...

Страница 30: ...s such modifying the setting should only be done under the guidance of Optelian support personnel 1 In the shelf view of the ONM or OSM double click the card or right click the card and choose Card Co...

Страница 31: ...lf in which the RGN 3GSF card is installd appropriate Optelian mounting shelf documentation Events are generated to provide information to the user that the system status has changed or a system proce...

Страница 32: ...cycle the card Replace the module if the failure persists OK No alarms are present N A None PowerA Faulty power supply A Minor Check Power Supply A Check if other cards in the shelf are reporting the...

Страница 33: ...Major Insert a valid Optelian SFP module Refer to the Optelian Pluggable Modules Product Guide document number 3019 4100 Reconfigure the card to allow third party SFP modules Refer to Configure card...

Страница 34: ...izing or experiencing a power fault condition ALM Alarm Off There are no alarms on the card Green The card is initializing Amber There is a minor alarm on the card or a port Red There is a major or cr...

Страница 35: ...REV 11 31 Customer Support Customer support is available 7 days a week 24 hours a day and can be contacted as follows North America 1 877 225 9428 International 1 613 287 2000 ext 2200 E mail techsupp...

Отзывы: