Scan Bed Motor Fault
Detected
This event can occur during a job activation of
the scan bed motor and a stall, over-current,
under-current, thermal warning or thermal
shutdown is detected by the stepper controller.
Stacker Motor Fault
Detected
This event can occur during a job activation of
the stacker motor and a stall, over-current,
under-current, thermal warning or thermal
shutdown is detected by the stepper controller.
ID1 Assist Verify Jammed
This event can occur during a run when the
sensor ID1 ASSIST VERIFY sensor is blocked
longer than the configurable amount of time has
allowed. The
id assist sensor jammed time
(5000)
machine parameter configures this
timeout. The default is 5000 milliseconds or 5
seconds.
Servo Fuse 1 Fault
Detected
This event can occur during a run when the fuse
for the servo motor, which controls the upstream
or right-hand pre-feed arm, is detected to be
open or blown.
Servo Fuse 2 Fault
Detected
This event can occur during a run when the fuse
for the servo motor, which controls the
downstream or left-hand pre-feed arm, is
detected to be open or blown.
Roller Bed Fan Fault
Detected
This event can occur during a run when the fan
for the roller bed motor is not detected as
operating.
Feeder Fan Fault
Detected
This event can occur during a run when the fan
for the feeder motor is not detected as
operating.
Table 11: Reasons for jams (continued)
Содержание FalconV
Страница 5: ...5 FalconV User Manual Standard Scanning OPEX Corporation Performance Details statistics 119...
Страница 6: ...6 FalconV User Manual Standard Scanning OPEX Corporation...
Страница 79: ...Operation 79 FalconV User Manual Standard Scanning OPEX Corporation Figure 21 XML Batch Output file example...
Страница 82: ...82 Operation FalconV User Manual Standard Scanning OPEX Corporation Figure 24 Ending the job...
Страница 110: ...110 Maintenance FalconV User Manual Standard Scanning OPEX Corporation...