Object Dictionary
414
ZW User's Manual
• Data relating to TASK 1 processing item "measurement point" is stored.
• The measurement point data of TASK 2 to 4 is stored to:
TASK 2: Index 3110 hex
TASK 3: Index 311A hex
TASK 4: Index 3124 hex
Sub-index 6: Parameter K
Setting range: -999999999 to
999999999
Unit:
Factory setting:
Size: 4 bytes (INT32)
Access: RW
PDO map: Not possible
Sub-index 7: Parameter M
Setting range: -100 to 100
Unit:
Factory setting:
Size: 4 bytes (INT32)
Access: RW
PDO map: Not possible
Sub-index 8: Parameter N
Setting range: -100 to 100
Unit:
Factory setting:
Size: 4 bytes (INT32)
Access: RW
PDO map: Not possible
Sub-index 9: Measurement Area
Setting range: 0 to 1
Unit:
Factory setting:
Size: 4 bytes (U32)
Access: RW
PDO map: Not possible
Sub-index 10: Measurement Result
Setting range:
Unit: nm
Factory setting:
Size: 4 bytes (INT32)
Access: RO
PDO map: Not possible
Sub-index 11: Measurement Value (Top)
Setting range:
Unit: nm
Factory setting:
Size: 4 bytes (INT32)
Access: RO
PDO map: Not possible
Sub-index 12: Measurement Value (End)
Setting range:
Unit: nm
Factory setting:
Size: 4 bytes (INT32)
Access: RO
PDO map: Not possible
3107 hex
Scaling (Task 1)
Sub-index 0: Number of entries
Setting range:
Unit:
Factory setting:
Size: 1 byte (U8)
Access: RO
PDO map: Not possible
Sub-index 1: Scaling Mode
Setting range: 0 to 3
Unit:
Factory setting:
Size: 4 bytes (U32)
Access: RW
PDO map: Not possible
Sub-index 2: Span
Setting range: -20000 to 20000
Unit:
Factory setting:
Size: 4 bytes (INT32)
Access: RW
PDO map: Not possible
Sub-index 3: Offset
Setting range: -999999999 to
999999999
Unit:
Factory setting:
Size: 4 bytes (INT32)
Access: RW
PDO map: Not possible
Содержание ZW-C1*AT
Страница 17: ...ZW User s Manual 1 15 ...
Страница 19: ...1 Basic configuration Basic configuration 1 1 ZW series Displacement Sensors 18 1 2 Basic Operation Flow 19 ...
Страница 54: ...Installing the Sysmac Studio 52 ZW User s Manual MEMO ...
Страница 74: ...Operating with Sensor Controller 72 ZW User s Manual MEMO ...
Страница 120: ...Setting the System 118 ZW User s Manual MEMO ...
Страница 138: ...Controll input signal with PC tool 136 ZW User s Manual MEMO ...
Страница 262: ...No protocol Connection 260 ZW User s Manual MEMO ...
Страница 270: ...Offline Debugging of the Sensor Control Program and Sensor Operation 268 ZW User s Manual MEMO ...
Страница 271: ...8 Troubleshooting Troubleshooting 8 1 Error Messages 270 8 2 Troubleshooting 284 ...
Страница 358: ...Connecting by No protocol Communications 356 ZW User s Manual MEMO ...
Страница 449: ......