Search from Menu Tree
290
ZW User's Manual
Setting
Option/Setting Range
Pages
I/O setting
[I/O]
Non-measurement
setting
[HLD.RST]
Non-measurement
setting
[HLD.RST]
Keep [KEEP]/Clamp [CLAMP]
*
Analog
output
[ANALOG]
Current output: MIN [MIN]
(approx. 3.4 mA)/4mA/5mA/..../19mA/
20mA/MAX [MAX]
(approx. 21mA) (default value: MAX)
Voltage output: MIN [MIN]
(approx. -10.8V)/-10V/-9V/.../9V/10V/
MAX [MAX] (approx. 10.8V)
(default value: MAX)
Judgment
[JUDGE]
Output target
[OUTPUT]
Output target
[OUTPUT]
TASK1 [TASK1]
*
/TASK2 [TASK2]/
TASK3 [TASK3]/TASK4 [TASK4]
Hysteresis
[HYS]
Hysteresis
[HYS]
0 to 99.9999 mm
(default value: 0.05% of measuring
range)
Timer
[TIMER]
TIMER
[TIMER]
Off
*
[OFF]/Off delay [OFF.DLY]/
On delay [ONDLY]/One shot [1SHOT]
Timer time
[TIME]
1 to 5000 ms (default value: 1)
Analog output
[ANALOG]
Output
destination
*
[V OR C]
Output
destination
[V OR C]
Voltage output
*
/Current output
Output target
[OUTPUT]
Output target
[OUTPUT]
Off [OFF]/TASK1 [TASK1]
*
/
TASK2 [TASK2]/TASK3 [TASK3]/
TASK4 [TASK4]
Monitor focus
[FOCUS]
Focus
[FOCUS]
Off [OFF]
*
/On [ON]
Focus
current/
voltage 1
[CUR1]/
[VOLT1]
Current: 4/5/6/7/8/9/10/11/12/13/14/15/
16/17/18/19/20mA (default value: 4mA)
Current: -10/-9/-8/-7/-6/-5/-4/-3/-2/-1/
0/1/2/3/4/5/6/7/8/9/10V
(default value: -10V)
Measurement
value 1
[MEAS1]
-999.999999 to 999.999999 mm
(default value: -0.5)
Focus
current/
voltage 2
[CUR2]/
[VOLT2]
Current: 4/5/6/7/8/9/10/11/12/13/14/15/
16/17/18/19/20mA (default value: 20mA)
Current: -10/-9/-8/-7/-6/-5/-4/-3/-2/-1/
0/1/2/3/4/5/6/7/8/9/10V
(default value: 10V)
Measurement
data2
[MEAS2]
-999.999999 to 999.999999 mm
(default value: 0.5)
Calibration
[CALIB]
Calibration
[CALIB]
Off
*
/On
Calibration
current/
voltage 1
[CUR1]/
[VOLT1]
Current: 4/5/6/7/8/9/10/11/12/13/14/15/
16/17/18/19/20mA (default value: 4mA)
Current: -10/-9/-8/-7/-6/-5/-4/-3/-2/-1/
0/1/2/3/4/5/6/7/8/9/10V
(default value: -10V)
Calibration
value 1
[ADJ1]
-999 to 999 (default value: 0)
Calibration
current/
voltage 2
[CUR2]/
[VOLT2]
Current: 4/5/6/7/8/9/10/11/12/13/14/15/
16/17/18/19/20mA (default value: 20mA)
Current: -10/-9/-8/-7/-6/-5/-4/-3/-2/-1/
0/1/2/3/4/5/6/7/8/9/10V
(default value: 10V)
Calibration
value 2
[ADJ2]
-999 to 999 (default value: 0)
*
The same "OUTPUT" is set for all banks. The output destination cannot be set separately for individual banks.
Содержание ZW-C1*AT
Страница 17: ...ZW User s Manual 1 15 ...
Страница 19: ...1 Basic configuration Basic configuration 1 1 ZW series Displacement Sensors 18 1 2 Basic Operation Flow 19 ...
Страница 54: ...Installing the Sysmac Studio 52 ZW User s Manual MEMO ...
Страница 74: ...Operating with Sensor Controller 72 ZW User s Manual MEMO ...
Страница 120: ...Setting the System 118 ZW User s Manual MEMO ...
Страница 138: ...Controll input signal with PC tool 136 ZW User s Manual MEMO ...
Страница 262: ...No protocol Connection 260 ZW User s Manual MEMO ...
Страница 270: ...Offline Debugging of the Sensor Control Program and Sensor Operation 268 ZW User s Manual MEMO ...
Страница 271: ...8 Troubleshooting Troubleshooting 8 1 Error Messages 270 8 2 Troubleshooting 284 ...
Страница 358: ...Connecting by No protocol Communications 356 ZW User s Manual MEMO ...
Страница 449: ......