
No-protocol Connection
ZW User's Manual
243
6
Commun
ication
s with Exte
rnal De
vi
ces
Zero reset execution command <ZR command>
Execute a zero reset for the specified task.
<Command format>
<Response format>
Normal processing
• If the task number is omitted, the zero reset is executed for the task of which the result is currently displayed.
• If "4" is set for the task number, the zero reset is executed for all tasks.
When a command was not successfully processed
<Parameter explanation>
Parameter
Description
Task number
Specifies the number of the task for which the zero reset is to be executed.
0: TASK1
1: TASK2
2: TASK3
3: TASK4
4: TASK1 to 4
CR
R
Z
↑
Task n
u
m
b
er
↑
Space
O
K
CR
E
R
CR
Содержание ZW-C1*AT
Страница 17: ...ZW User s Manual 1 15 ...
Страница 19: ...1 Basic configuration Basic configuration 1 1 ZW series Displacement Sensors 18 1 2 Basic Operation Flow 19 ...
Страница 54: ...Installing the Sysmac Studio 52 ZW User s Manual MEMO ...
Страница 74: ...Operating with Sensor Controller 72 ZW User s Manual MEMO ...
Страница 120: ...Setting the System 118 ZW User s Manual MEMO ...
Страница 138: ...Controll input signal with PC tool 136 ZW User s Manual MEMO ...
Страница 262: ...No protocol Connection 260 ZW User s Manual MEMO ...
Страница 270: ...Offline Debugging of the Sensor Control Program and Sensor Operation 268 ZW User s Manual MEMO ...
Страница 271: ...8 Troubleshooting Troubleshooting 8 1 Error Messages 270 8 2 Troubleshooting 284 ...
Страница 358: ...Connecting by No protocol Communications 356 ZW User s Manual MEMO ...
Страница 449: ......