
EtherNet/IP Connection
206
ZW User's Manual
●
Settings in the ZW (Device Parameter Settings)
* The packet interval (RPI) is set in the connection settings between the PLC and the Sensor. No setting is required here.
1
Right-click the ZW in the network on the Network Configurator and select [Parameter] - [Edit].
2
The Edit Device Parameters Dialog Box will be displayed. Make the required settings.
Parameter name
Value
Setting range
001 Input Size
The total size of response area and output area
56
002 Output Size
The data size of command area
24
003 RPI
*
The requested packet interval
10000
Содержание ZW-C1*AT
Страница 17: ...ZW User s Manual 1 15 ...
Страница 19: ...1 Basic configuration Basic configuration 1 1 ZW series Displacement Sensors 18 1 2 Basic Operation Flow 19 ...
Страница 54: ...Installing the Sysmac Studio 52 ZW User s Manual MEMO ...
Страница 74: ...Operating with Sensor Controller 72 ZW User s Manual MEMO ...
Страница 120: ...Setting the System 118 ZW User s Manual MEMO ...
Страница 138: ...Controll input signal with PC tool 136 ZW User s Manual MEMO ...
Страница 262: ...No protocol Connection 260 ZW User s Manual MEMO ...
Страница 270: ...Offline Debugging of the Sensor Control Program and Sensor Operation 268 ZW User s Manual MEMO ...
Страница 271: ...8 Troubleshooting Troubleshooting 8 1 Error Messages 270 8 2 Troubleshooting 284 ...
Страница 358: ...Connecting by No protocol Communications 356 ZW User s Manual MEMO ...
Страница 449: ......