Parallel I/O connection
150
ZW User's Manual
Settings for Bank Control
This section describes the settings for controlling banks by using parallel I/O.
Selecting banks
The bank is selected in combinations of the bank select input signals (BANK_SEL1 to 3).
• Bank switching is begun 0.2 seconds after the input state changes.
• At most it takes about 100ms to switch banks.
• During bank switching, the BUSY output becomes ON.
• If the bank mode is set to [JUDGE], the bank cannot be switched at the external signal input because the number of
banks increases to 32.
Outputting the currently selected bank number
The currently selected bank number is output.
The output bank number depends on the combination of the bank number output signals (BANK_OUT1 to 3).
Clamp values can also be set with key operations on the Sensor Controller.
Bank selection input 1
(BANK_SEL1)
Bank selection input 2
(BANK_SEL2)
Bank selection input 3
(BANK_SEL3)
Selected bank
OFF
OFF
OFF
BANK1
ON
OFF
OFF
BANK2
OFF
ON
OFF
BANK3
ON
ON
OFF
BANK4
OFF
OFF
ON
BANK5
ON
OFF
ON
BANK6
OFF
ON
ON
BANK7
ON
ON
ON
BANK8
Bank number output 1
(BANK_OUT1)
Bank number output 2
(BANK_OUT2)
Bank number output 3
(BANK_OUT3)
Output bank
OFF
OFF
OFF
BANK1
ON
OFF
OFF
BANK2
OFF
ON
OFF
BANK3
ON
ON
OFF
BANK4
OFF
OFF
ON
BANK5
ON
OFF
ON
BANK6
OFF
ON
ON
BANK7
ON
ON
ON
BANK8
Note
Important
Содержание ZW-C1*AT
Страница 17: ...ZW User s Manual 1 15 ...
Страница 19: ...1 Basic configuration Basic configuration 1 1 ZW series Displacement Sensors 18 1 2 Basic Operation Flow 19 ...
Страница 54: ...Installing the Sysmac Studio 52 ZW User s Manual MEMO ...
Страница 74: ...Operating with Sensor Controller 72 ZW User s Manual MEMO ...
Страница 120: ...Setting the System 118 ZW User s Manual MEMO ...
Страница 138: ...Controll input signal with PC tool 136 ZW User s Manual MEMO ...
Страница 262: ...No protocol Connection 260 ZW User s Manual MEMO ...
Страница 270: ...Offline Debugging of the Sensor Control Program and Sensor Operation 268 ZW User s Manual MEMO ...
Страница 271: ...8 Troubleshooting Troubleshooting 8 1 Error Messages 270 8 2 Troubleshooting 284 ...
Страница 358: ...Connecting by No protocol Communications 356 ZW User s Manual MEMO ...
Страница 449: ......