Adjusting the analog output value
Adjusting the analog output value p.143
As an example, the following explains the procedure for correcting 4 mA output (Point1) and 20 mA output
(Point2).
Operating procedure
Steps
Key operation
Display
Description
1 to 3
For moving to "ANALOG", see steps 1 to 3 in p.338.
4
Press the
/
keys to select "CALIB" and press the
key.
5
Select analog output correction ON/OFF.
The current setting value is displayed on the sub-display.
Press
/
key to enter editing mode and the sub-display blinks.
In this example, select "ON" and press the
key.
6
Set the reference value of the point1.
The current set value for the point1 is displayed on the sub-display.
Press
/
key to enter editing mode and the sub-display blinks.
In this example, select "4mA" and press the
key.
7
Set the adjustment value of the point1.
Press the
/
/
/
keys to input the adjustment value and
press the
key.
Next, check the ammeter value and press the
key.
To re-adjust, press the
key.
8
Set the reference value of the point2.
The current set value for the point2 is displayed on the sub-display.
Press
/
key to enter editing mode and the sub-display blinks.
In this example, select "20mA" and press the
key.
9
Set the adjustment value of the point2.
Press the
/
/
/
keys to input the adjustment value and
press the
key.
Next, check the ammeter value and press the
key.
To re-adjust, press the
key.
10
"OK/CAN" is displayed on the sub-display.
Press the
key to execute correction or
key to cancel.
11
Press and hold the
key for two seconds to enter the RUN mode.
Содержание ZW-C1*AT
Страница 17: ...ZW User s Manual 1 15 ...
Страница 19: ...1 Basic configuration Basic configuration 1 1 ZW series Displacement Sensors 18 1 2 Basic Operation Flow 19 ...
Страница 54: ...Installing the Sysmac Studio 52 ZW User s Manual MEMO ...
Страница 74: ...Operating with Sensor Controller 72 ZW User s Manual MEMO ...
Страница 120: ...Setting the System 118 ZW User s Manual MEMO ...
Страница 138: ...Controll input signal with PC tool 136 ZW User s Manual MEMO ...
Страница 262: ...No protocol Connection 260 ZW User s Manual MEMO ...
Страница 270: ...Offline Debugging of the Sensor Control Program and Sensor Operation 268 ZW User s Manual MEMO ...
Страница 271: ...8 Troubleshooting Troubleshooting 8 1 Error Messages 270 8 2 Troubleshooting 284 ...
Страница 358: ...Connecting by No protocol Communications 356 ZW User s Manual MEMO ...
Страница 449: ......