Parallel I/O connection
ZW User's Manual
153
6
Commun
ication
s with Exte
rnal De
vi
ces
Hold (peak/bottom/peak to peak/average)
Explanation of operations
(1) The TIMING input is turned ON.
(2) During the TIMING input minimum time, when the TIMING input is ON, sampling is started and the BUSY
output is turned ON.
(3) The TIMING input is turned OFF.
(4) After the TIMING input turns OFF, sampling is ended and the judgment results are output. The BUSY output
is also turned OFF.
(5) After the judgment result output, the analog output is updated.
(6) The RESET input is turned ON. If the RESET input is turned ON during the RESET input minimum time, the
measured value is reset.
(7) The judgment result is reset.
(8) After the judgment result reset, the analog output is reset.
(9) The RESET input is turned OFF.
When the setting for non-measurement is "CLAMP", if the sampling value is an abnormal value or an undetermined
value
*
, sampling is not executed. If sampling has been started, it is stopped. The output value is as follows.
• Hold the clamp value.
• To start and continue sampling even if a sampling value is an abnormal value or an undetermined value, set "KEEP"
as the non-measurement setting.
*: After the start of measurement, if measurement results are not obtained the number of times required to take the
average, the measurement result is not applied.
Item
Min.
Max.
T3
Response time of analog output
0.1 ms
T4
TIMING input/RESET input minimum time
3ms+T0
T5
Input response time
2ms+T0
3ms+T0 × 2
(2)
(3)
T4
(4) (5)
T5
T4
T3
TIMI
N
G inp
u
t
RESET inp
u
t
BUSY o
u
tp
u
t
J
u
dgment o
u
tp
u
t
(HIGH/PASS/LO
W
)
Analog o
u
tp
u
t
(6)
T5
(
8
)
(7)
T5
(1)
O
N
OFF
O
N
OFF
O
N
OFF
T3
(9)
Important
Содержание ZW-C1*AT
Страница 17: ...ZW User s Manual 1 15 ...
Страница 19: ...1 Basic configuration Basic configuration 1 1 ZW series Displacement Sensors 18 1 2 Basic Operation Flow 19 ...
Страница 54: ...Installing the Sysmac Studio 52 ZW User s Manual MEMO ...
Страница 74: ...Operating with Sensor Controller 72 ZW User s Manual MEMO ...
Страница 120: ...Setting the System 118 ZW User s Manual MEMO ...
Страница 138: ...Controll input signal with PC tool 136 ZW User s Manual MEMO ...
Страница 262: ...No protocol Connection 260 ZW User s Manual MEMO ...
Страница 270: ...Offline Debugging of the Sensor Control Program and Sensor Operation 268 ZW User s Manual MEMO ...
Страница 271: ...8 Troubleshooting Troubleshooting 8 1 Error Messages 270 8 2 Troubleshooting 284 ...
Страница 358: ...Connecting by No protocol Communications 356 ZW User s Manual MEMO ...
Страница 449: ......