65
Z500
Operation Manual
SECTI
ON 4
SECTION 4
Menus for Expert Menu
Operational Flow
CHECK
To use the position compensation function, set
Compensatn
and
Meas set
in this order.
#1
Registering the Reference Position
Register the position to be used for a reference for position compensation.
Before setting the necessary items, place the workpiece at the correct position.
In the example provided below, the procedure for compensating under the
following conditions is explained.
Reference height measurement point
Registering
the Reference
Position
#1
Page 65
#2
Page 69
Set the
Compensation
Method
Measurement
point (Average)
Reference height
Reference position
Measurement
point (Edge position)
Region
Edge level
Selection
Description
Average
Define the average profile position within a specified region as the
measurement point.
Peak
Define the peak profile position within a specified region as the
measurement point.
Bottom
Define the bottom profile position within a specified region as the
measurement point.
Region
Peak
Bottom
St
e
p
2
St
e
p
1
St
e
p
3
St
e
p
4
St
e
p
5
St
e
p
6
St
e
p
7
Содержание Z500 Series
Страница 20: ...18 SECTION 1 1 2 Operational Flow Z500 Operation Manual SECTION 1 Features MEMO ...
Страница 40: ...38 SECTION 2 2 4 Saving Settings and Exiting the Z500 Z500 Operation Manual SECTION 2 Basic Operations MEMO ...
Страница 144: ...142 SECTION 5 5 8 Backing Up Data to a Computer Backup Z500 Operation Manual SECTION 5 Other Functions MEMO ...
Страница 184: ...182 7 3 Analog Output SECTION 7 Z500 Operation Manual SECTION 7 I O Format MEMO ...