8-1 Troubleshooting
This section lists the errors that may occur during Z500 operation, along with their probable causes and
remedies.
The letters used in the reference page column represent the following reference materials:
Setup: Setup Manual
Operation: Operation Manual (this manual)
Error message
Causes and remedies
Reference
No edge detected.
Redo settings.
- Is the workpiece inside the measurement range?
- Is the measurement performed correctly?
Check this on the image monitor screen.
Reason
The edge to be determined as the reference position could not
be found during reference registration.
Setup: page 28
Operation: page 30
Environment is set to
select scenes via terminal
block.
Using the
System/Environment
screen check if
Scene
has
been set correctly.
Reason
An error has occurred in
Scene
.
Operation: page 146
The reference height and
position have been
updated.
Check the settings for
measurement items.
Check whether the setting contents of the measurement items
are correct.
Reason
The reference was registered after the measurement items
had been set. When using the position compensation function,
set
Compensatn
and
Meas set
in this order.
Operation: page 70
Too many items to
register.
Perform registration after
deleting unnecessary
items.
Delete all unnecessary measurement items, and then set the
necessary items again.
Reason
The number of measurement points exceeds the allowable
limit of the Z500.
Operation: page 87
No measurement point
detected.
Redo settings.
- Is the workpiece inside the measurement range?
- Is the measurement performed correctly?
Check this on the image monitor screen.
Reason
The edge to be determined as the reference position could not
be found during reference registration.
Setup: page 28
Operation: page 30
Meas method will be
changed.
All scene data will be
cleared.
Data integration cannot be ensured when the measurement
method is changed. All settings for scene data are returned to
their default settings.
——
No more functions
settable.
Redo the settings.
Change the setting of unnecessary functions.
Example
- Set
Conditions/Details/Profile
to
None.
- Set the position compensation to
None
.
- Delete all unnecessary measurement items.
- Delete
Output/Analog/Profile.
Operation: page 96
Operation: page 64
Operation: page 70
Operation: page 100
Содержание Z500 Series
Страница 20: ...18 SECTION 1 1 2 Operational Flow Z500 Operation Manual SECTION 1 Features MEMO ...
Страница 40: ...38 SECTION 2 2 4 Saving Settings and Exiting the Z500 Z500 Operation Manual SECTION 2 Basic Operations MEMO ...
Страница 144: ...142 SECTION 5 5 8 Backing Up Data to a Computer Backup Z500 Operation Manual SECTION 5 Other Functions MEMO ...
Страница 184: ...182 7 3 Analog Output SECTION 7 Z500 Operation Manual SECTION 7 I O Format MEMO ...