32
SE
CTION 2
2-3 Screen
Typ
es and
Disp
lay Meth
od
s
Z500
Operation Manual
SECTION 2
Basic Operations
Measurement Result Display
Check whether the measurements are correctly performed.
The measurement points and the measurement values are displayed.
CHECK
Offset can be set for Force-zero.
REFERENCE
Refer to page 84.
PASS
mm
+0005.18800
9.96ms
OUT 0
FAR
NEAR
[ 15]
[ 170]
[ .]
[ ]
BRIGHT
DARK
Zero's OFF
Sen0
LV
PEAK
LV
PEAK
Sen1
S+ / :Display S+ENT:Adjust
Scn 0 Run
Measurement points (red)
Forced-zero
Zero's OFF: Forced-zero not executed
Zero's ON: Forced-zero executed
Judgment results
Measurement value
The measurement value is displayed
in green if the judgment result is PASS.
It is displayed in red if the judgment
result is HIGH, LOW, or ERROR.
Output number
The output number for the currently displayed
measurement result is displayed.
The measured points are displayed.
No point is displayed when the measurement is in error.
The level and range necessary for the determination of
measurement points are represented by thin lines.
(In this example, the distance between the 2 points is
measured.)
HIGH : Greater than the judgment upper limit
PASS : Within the judgment limits
LOW : Less than the judgment lower limit
ERROR : Measurement error
-The workpiece is out of the measurement range
-The light density is insufficient
-Information on the measurement point
cannot be obtained, or other cases
RESET: No-measurement state
LD-OFF: LD-OFF input
Содержание Z500 Series
Страница 20: ...18 SECTION 1 1 2 Operational Flow Z500 Operation Manual SECTION 1 Features MEMO ...
Страница 40: ...38 SECTION 2 2 4 Saving Settings and Exiting the Z500 Z500 Operation Manual SECTION 2 Basic Operations MEMO ...
Страница 144: ...142 SECTION 5 5 8 Backing Up Data to a Computer Backup Z500 Operation Manual SECTION 5 Other Functions MEMO ...
Страница 184: ...182 7 3 Analog Output SECTION 7 Z500 Operation Manual SECTION 7 I O Format MEMO ...