Z500
Operation Manual
6-5
Com
p
en
satin
g In
stallation
Er
ro
r (Slant correct)
SECTI
ON 6
149
SECTION 6
System Settings
6-5 Compensating Installation Error (
Slant correct
)
The profile of a workpiece may sometimes be slanted in the Image Monitor, even when it is measured
after being held horizontally. This is mainly caused by erroneous orientation of the sensor.
The installation error compensation function will calculate automatically the value for slant correction of
the sensor, and thus permits high accuracy measurement of workpiece profiles.
The value for slant compensation will be calculated specifically for the sensor that has currently been
used for the measurement (Sensor 0 or Sensor 1) and the measurement method (Wide or Zoom).
CHECK
The value that has been set for
Slant correct
is not included in the system data.
1.
Install a horizontal base.
2.
Enter System Mode and select
Slant
correct
.
REFERENCE
Refer to page 144.
The selections will be displayed.
3.
Select
Setting
.
Scn 0 Run
Scn 0 Run
Before applying the installation
error compensation function
The profile in the display is distorted
because of slanted installation of the
sensor.
After application of the installation
error compensation function
Distortion of the profile is compensated.
(Though the CCD image is distorted,
it does not affect the measurement.)
CCD Image
Profile (Yellow)
Comm
Environment
Download
Slant correct
Initialize
V e r s i o n
Scn 0 System
Setting
Clear
Содержание Z500 Series
Страница 20: ...18 SECTION 1 1 2 Operational Flow Z500 Operation Manual SECTION 1 Features MEMO ...
Страница 40: ...38 SECTION 2 2 4 Saving Settings and Exiting the Z500 Z500 Operation Manual SECTION 2 Basic Operations MEMO ...
Страница 144: ...142 SECTION 5 5 8 Backing Up Data to a Computer Backup Z500 Operation Manual SECTION 5 Other Functions MEMO ...
Страница 184: ...182 7 3 Analog Output SECTION 7 Z500 Operation Manual SECTION 7 I O Format MEMO ...