156
7-1 Term
inal B
locks
SE
CTION 7
Z500
Operation
Manual
SECTION 7
I/O Format
Note 1:
Will be turned ON when all measurement results are judged to be PASS for the already registered output
numbers. This can be used for the comprehensive judgment. However, the OFF delay will not function.
Note 2:
Will be turned ON if at least one of the measurement results is judged to be ERROR for the already registered
output numbers. This can be used to identify that an error has occurred. However, the OFF delay will not
function.
Note 3:
Will be turned ON during measurement. Will be turned OFF while the scene is changed or set.
Note 4:
Will be turned ON during Trigger measurement. Use this terminal to confirm whether or not the trigger is
operating normally when self-trigger is set as the trigger input method.
Judgment output B
Judgment results (OK or NG) for the measurement values of OUT0 through
OUT7 are output to terminals DO0 through DO7.
Output Contents and Terminal Allocation
Note 1:
Will be turned ON when all measurement results are judged to be PASS for the
already registered output numbers. This can be used for the comprehensive
judgment. However, the OFF delay will not function.
Note 2:
Will be turned ON if at least one of the measurement results is judged to be
ERROR for the already registered output numbers. This can be used to identify
that an error has occurred. However, the OFF delay will not function.
Note 3:
Will be turned ON during measurement. Will be turned OFF while the scene is
changed or set.
Note 4:
Will be turned ON during Trigger measurement. Use this terminal to confirm
whether or not the trigger is operating normally when self-trigger is set as the
trigger input method.
CHECK
All output terminals turn OFF when the mode is switched from Run Mode.
CHECK
The initial signal of the output terminals is OFF. The terminals, however, may turn ON for
approximately 0.5 s when the power is turned ON. Be sure to allow for this when conneting
to an external device.
Result
Meaning
OK
PASS (Judgment lower limit Measurement value Judgment upper
limit): Turns ON
NG
HIGH (Judgment upper limit < Measurement value), LOW (Judgment
lower limit > Measurement value), or ERROR (The Sensor cannot
perform measurement): Turns ON
Output contents
Output Terminals
OUT0
OK/NG
DO0
OUT1
OK/NG
DO1
OUT2
OK/NG
DO2
OUT3
OK/NG
DO3
OUT4
OK/NG
DO4
OUT5
OK/NG
DO5
OUT6
OK/NG
DO6
OUT7
OK/NG
DO7
Not used
DO8 to DO15
ALL-PASS (See note 1.)
DO16
ERROR (See note 2.)
DO17
RUN (See note 3.)
DO18
BUSY (See note 4.)
DO19
Содержание Z500 Series
Страница 20: ...18 SECTION 1 1 2 Operational Flow Z500 Operation Manual SECTION 1 Features MEMO ...
Страница 40: ...38 SECTION 2 2 4 Saving Settings and Exiting the Z500 Z500 Operation Manual SECTION 2 Basic Operations MEMO ...
Страница 144: ...142 SECTION 5 5 8 Backing Up Data to a Computer Backup Z500 Operation Manual SECTION 5 Other Functions MEMO ...
Страница 184: ...182 7 3 Analog Output SECTION 7 Z500 Operation Manual SECTION 7 I O Format MEMO ...