135
Z500
Operation Manual
SECTION 5
5-7 C
h
eckin
g
the L
ine Be
am Po
sition
(Su
rro
un
din
g
im
age)
SECTION 5
Other Functions
5-7 Checking the Line Beam Position (
Surrounding image
)
Displays images of the area surrounding the part that the line beam strikes. Whether or not the line beam
strikes the part required for measurement can be checked on the screen. This function is useful when the
Sensor is mounted inside an installation and the measurement area cannot be checked directly.
CHECK
If the Z500-SW2 Sensor is connected, move the beam cover lever to the left.
REFERENCE
Refer to page 20,
Setup Manual.
1.
Enter Tools Mode.
REFERENCE
Refer to page 128.
The selections will be displayed.
2.
Select
Surrounding image
.
Two Sensor
The sensor selections will be displayed.
Select the number of the sensor used for
displaying the image.
The screen for recording images will be displayed.
3.
Press the
TRIG
Key.
An image of the area surrounding the line beam is displayed.
Z500-SW17: Displays the image for the shutter time displayed.
Z500-SW2: The Z500 will search for the most suitable shutter time and will display the image.
CHECK
If the image is difficult to see clearly, adjust the image.
Change the shutter speed using the
Up
and
Down
Keys.
Use these keys together with the
SHIFT
Key to move the cursor quickly.
Adjust the sensitivity level using the
Left
and
Right
Keys.
Image
Brighter
Darker
Shutter time
10s
0.05s
Sensitivity level
31
0
Press the
ENT
Key to switch the lighting. (ON/OFF) (If the Z500-SW2 Sensor is
connected.)
4.
To stop displaying, press the
ESC
Key.
A Tools Mode screen will return.
Test
Surrounding image
Backup
Scn 0 Tools
Shutter=[ 0.01]s / :Change
Sensitivty=LV[ 11] / :Change
TRG:Get image
Содержание Z500 Series
Страница 20: ...18 SECTION 1 1 2 Operational Flow Z500 Operation Manual SECTION 1 Features MEMO ...
Страница 40: ...38 SECTION 2 2 4 Saving Settings and Exiting the Z500 Z500 Operation Manual SECTION 2 Basic Operations MEMO ...
Страница 144: ...142 SECTION 5 5 8 Backing Up Data to a Computer Backup Z500 Operation Manual SECTION 5 Other Functions MEMO ...
Страница 184: ...182 7 3 Analog Output SECTION 7 Z500 Operation Manual SECTION 7 I O Format MEMO ...