SECTION 7
I/O Format
7-3 Analog Output
Measurement results can be output as current in the range 4 to 20 mA and as voltage in the range -5 to
5 V.
REFERENCE
For details on setting output contents, refer to page 100.
CHECK
Output During Reset Input
During restart (approx. 20 s after power is turned ON), 0 V and 12 mA are output to the
analog output terminals. Ensure that these outputs are not treated as actual signals at
external devices.
Outputting Measurement Values
When output numbers
OUT0
through
OUT7
have been set to
Output
, the
measured values will be output.
Outputting the Profile
When
Profile
has been set to
Output
, the analog signals of the profile (height
distribution of 126 points) will be output.
By inputting analog output signals to a personal computer via an A/D converter,
profiles can be measured in terms of height distribution.
Connection Example
Z500-SW17
Z500-MC10
Monitor terminals
Monitor output
Co A/D converter
Monitor
Workpiece
Analog
output terminals
Analog profile output
MULTI-DIMENSION CONTROLLER
POWER
Содержание Z500 Series
Страница 20: ...18 SECTION 1 1 2 Operational Flow Z500 Operation Manual SECTION 1 Features MEMO ...
Страница 40: ...38 SECTION 2 2 4 Saving Settings and Exiting the Z500 Z500 Operation Manual SECTION 2 Basic Operations MEMO ...
Страница 144: ...142 SECTION 5 5 8 Backing Up Data to a Computer Backup Z500 Operation Manual SECTION 5 Other Functions MEMO ...
Страница 184: ...182 7 3 Analog Output SECTION 7 Z500 Operation Manual SECTION 7 I O Format MEMO ...