103
Z500
Operation Manual
SECTI
ON 4
SECTION 4
Menus for Expert Menu
Terminal Block Output
Judgment results can be output via the terminal block. The settings are enabled
for all output numbers.
The asterisk (*) indicates the default setting.
Note:
The GATE signal is output only when the
Trigger
is set to
External
or
Free
.
If the
Trigger
is not set, the GATE signal will always stay OFF regardless of the
settings of the GATE ON delay and GATE ON time.
CHECK
For details on I/O Format, refer to page 154.
CHECK
The setting can be performed through the adjustment menu.
REFERENCE
Refer to page 28.
Item
Selection/
Setting range
Description
Format
Judge output A*
Select this function to output the details of the
judgment (HIGH/PASS/LOW/ERROR).
The output includes the judgment results for
OUT0 through OUT3. Those for OUT4 through
OUT7 will not be output.
Judge output B
Judgment results for OUT0 through OUT7 will be
output in the form of OK or NG.
OK : PASS
NG : HIGH, LOW, ERROR
OFF delay
0 to 99999
(0*)
Set the OFF delay time N (sampling time
×
N).
Set a time that allows the external device to input
the result.
GATE ON delay
(See note.)
1.0 to 1000.0ms
(1.0ms*)
Set the time from when the result is output to the
terminals to when the GATE signal is turned ON.
The time to wait until stable output data can be
obtained. Set this time longer than the data t
ransmission delay time to external devices.
GATE ON time
(See note.)
1.0 to 1000.0ms
(5.0ms*)
Set the length of time that the GATE signal
remains ON. Set a value so that the external
device can obtain the measurement result.
St
e
p
2
St
e
p
1
St
e
p
3
St
e
p
4
St
e
p
5
St
e
p
6
St
e
p
7
Содержание Z500 Series
Страница 20: ...18 SECTION 1 1 2 Operational Flow Z500 Operation Manual SECTION 1 Features MEMO ...
Страница 40: ...38 SECTION 2 2 4 Saving Settings and Exiting the Z500 Z500 Operation Manual SECTION 2 Basic Operations MEMO ...
Страница 144: ...142 SECTION 5 5 8 Backing Up Data to a Computer Backup Z500 Operation Manual SECTION 5 Other Functions MEMO ...
Страница 184: ...182 7 3 Analog Output SECTION 7 Z500 Operation Manual SECTION 7 I O Format MEMO ...