176
7-2 R
S
-232C
SE
CTION 7
Z500
Operation
Manual
SECTION 7
I/O Format
Commands that Save and Load Data
• DATASAVE
Function
……
Saves all data to flash memory.
DATASAVE
Command correctly saved
: OK
Command not correctly saved
: ER
NOTICE
Do not turn OFF the Z500's power until a response has been received.
• SCNLOAD
Function
……
Loads scene data from the host device to the Z500.
SCNLOAD <Scene number>
• Specify a scene number between 0 and 15. If no scene number is specified,
the data is loaded to the currently displayed scene.
• The data transfer is performed with XMODEM(-CRC or SUM) protocol. The
XMODEM(-1K) protocol is not supported.
• The Z500 sends a READY signal to the host device when the Z500 has
completed its initialization. Wait for the READY signal to be received at the
host device before starting the data transfer.
Data correctly loaded
: OK
Data not correctly loaded
: ER
Example
Input
delimiter
Output
delimiter
delimiter
Input
delimiter
Output
delimiter
delimiter
:
SCNLOAD 2
Data will be loaded to scene 2 from a host device.
:
OK
Input
delimiter
Output
delimiter
Содержание Z500 Series
Страница 20: ...18 SECTION 1 1 2 Operational Flow Z500 Operation Manual SECTION 1 Features MEMO ...
Страница 40: ...38 SECTION 2 2 4 Saving Settings and Exiting the Z500 Z500 Operation Manual SECTION 2 Basic Operations MEMO ...
Страница 144: ...142 SECTION 5 5 8 Backing Up Data to a Computer Backup Z500 Operation Manual SECTION 5 Other Functions MEMO ...
Страница 184: ...182 7 3 Analog Output SECTION 7 Z500 Operation Manual SECTION 7 I O Format MEMO ...