xv
Installation Precautions
3
• Provide a forced-air fan or air conditioning if the ambient temper-
ature might exceed 50
C.
Noise Resistance
Use the following measures to help increase noise resistance.
• Do not install V530-R150 components in a cabinet containing
high-voltage equipment.
• Do not install V530-R150 components within 200 mm of power
cables.
Cables
Always turn OFF the power before connecting or disconnecting
cables.
Cameras
The camera’s case is connected to the 0V line in the internal circuits.
Heed the following precautions to prevent noise interference.
• Do not ground the camera.
• Do not remove the base attached to the camera.
• Do not remove the core attached to the F150-VS camera cable.
Control Box
V530-R150
Louver
V530-R150
200 mm min.
200 mm min.
Power Cable