199
System
Section 6-4
1,2,3...
1.
Select a trigger mode for TRIG B.
2.
Select whether the OK/NG terminal is turned ON for an OK read-
ing or an NG reading.
3.
Set the output period for reading judgment. Set a value between
2.0 and 10000.0 ms that is greater than the rising time + output
time, and less than the reading interval. If the cycle is longer than
the reading interval, the output timing will fall behind as the read-
ings are repeated.
(The default setting is 10.0 ms.)
4.
Set the time from when the result is output to the terminal block
to when the GATE signal is turned ON. This time is used to wait
until the data output becomes stable. Set a time between 1.0 and
1000.0 ms that is longer than the delay time for the external de-
vice.
(The default setting is 1.0 ms.)
5.
Set the time during which the GATE signal is ON. Set a value be-
tween 1.0 and 1000.0 ms so that the external device can read the
reading judgment. (The default setting is 5.0 ms.)
Output Settings
Continuous
(Default)
Performs continuous reading while the TRIG B termi-
nal is turned ON. In this mode, the settings for reading
accuracy and the number of retries are invalid with
TRIG B input.
Level trig (trig-
ger)
Repeats reading until an OK (readable) reading judg-
ment is output while the TRIG B terminal is ON. In the
case of an NG (not readable) reading, the NG signal is
output when the TRIG B is turned OFF.
NG: ON
(Default)
The OK/NG terminal is turned ON for an NG reading.
OK: ON
The OK/NG terminal is turned ON for an OK reading.
Output Settings
Содержание V530-R150E-3 -
Страница 1: ...Cat No Z155 E1 01 2 Dimensional Code Reader Fixed Type V530 R150E 3 V530 R150EP 3 OPERATION MANUAL...
Страница 2: ...V530 R150E 3 V530 R150EP 3 2 Dimensional Code Reader Fixed Type Operation Manual Produced August 2001...
Страница 7: ......
Страница 9: ......
Страница 17: ......
Страница 27: ......
Страница 47: ......
Страница 63: ......
Страница 224: ...207 System Section 6 4 2 Set each item 3 Select End before leaving this screen...
Страница 226: ...209 System Section 6 4 2 Select the error method 3 Select End to leave this screen...
Страница 247: ...230 2 Dimensional Code Reader Section 8 1 8 1 2 Dimensional Code Reader V530 R150 Four 4 5 dia 165 min Unit mm...
Страница 263: ......
Страница 279: ......
Страница 281: ......
Страница 283: ......
Страница 289: ......