197
System
Section 6-4
forcibly switch the Programmable Controller to MONITOR
mode.
3964(R)
The 3964(R) procedure controls data transmission via a point-to-
point connection between a Siemens product and a communications
partner.
1,2,3...
1.
The character delay time defines the maximum amount of time
permitted between two incoming characters within a message
frame.
Select 20 ms to 655350 ms in 10-ms increments.
The shortest character delay time depends on the baud rate.
300 bits/s
60 ms
600 bits/s
40 ms
1200 bits/s
30 ms
2400 to 76800 bits/s
20 ms
(Default setting: 220 ms)
2.
The acknowledgment delay time defines the maximum amount of
time permitted for the partner’s acknowledgment to arrive during
connection setup (time between STX and partner’s DLE acknowl-
edgment) or release (time between DLE ETX and partner’s DLE
acknowledgment).
Select 20 ms to 655350 ms in 10-ms increments.
The shortest acknowledgment delay time (ADT) depends on the
baud rate.
300 bits/s
60 ms
600 bits/s
40 ms
1200 bits/s
30 ms
2400 to 76800 bits/s
20 ms
(Default setting: 2000 ms)
3964(R)
Cha. delay time
Ack. delay time
Setup att. count
trans. att. count
Master/Slave
:
:
:
:
:
[ 22]x10ms
[ 200]x10ms
[ 6]
[ 6]
Slave
Содержание V530-R150E-3 -
Страница 1: ...Cat No Z155 E1 01 2 Dimensional Code Reader Fixed Type V530 R150E 3 V530 R150EP 3 OPERATION MANUAL...
Страница 2: ...V530 R150E 3 V530 R150EP 3 2 Dimensional Code Reader Fixed Type Operation Manual Produced August 2001...
Страница 7: ......
Страница 9: ......
Страница 17: ......
Страница 27: ......
Страница 47: ......
Страница 63: ......
Страница 224: ...207 System Section 6 4 2 Set each item 3 Select End before leaving this screen...
Страница 226: ...209 System Section 6 4 2 Select the error method 3 Select End to leave this screen...
Страница 247: ...230 2 Dimensional Code Reader Section 8 1 8 1 2 Dimensional Code Reader V530 R150 Four 4 5 dia 165 min Unit mm...
Страница 263: ......
Страница 279: ......
Страница 281: ......
Страница 283: ......
Страница 289: ......