200
System
Section 6-4
These settings determine how data will be output through RS-232C
(Normal) communications.
1,2,3...
1.
Select whether or not to include the number of digits of Reading
Data. Select OFF or ON. (Default setting: OFF)
The number of digits are shown in bytes. A letter or a number is 1
digit. If the position and/or angle are attached, those digits will be
included in the total number of digits of Reading Data.
2.
Select whether or not to include the position (X,Y coordinates) of
the 2-dimensional code that was read. Select OFF or ON. (De-
fault setting: OFF)
3.
Select whether or not to include the angle of the 2-dimensional
code that was read. Select OFF or ON. (Default setting: OFF)
4.
When the V530-R150 is connected with a 1:1 connection, select
whether or not to use the Polling Command to control the timing
of Reading Data outputs. Select OFF or ON. (Default setting:
OFF)
ON: The Reading Data will not be output until the Polling Com-
mand is input
OFF: The Reading Data will be output immediately after it is read.
Example:
030 221223 060 200103 2 6 - ABCDEFG - 0815
Origin (0,0)
(511,483)
Содержание V530-R150E-3 -
Страница 1: ...Cat No Z155 E1 01 2 Dimensional Code Reader Fixed Type V530 R150E 3 V530 R150EP 3 OPERATION MANUAL...
Страница 2: ...V530 R150E 3 V530 R150EP 3 2 Dimensional Code Reader Fixed Type Operation Manual Produced August 2001...
Страница 7: ......
Страница 9: ......
Страница 17: ......
Страница 27: ......
Страница 47: ......
Страница 63: ......
Страница 224: ...207 System Section 6 4 2 Set each item 3 Select End before leaving this screen...
Страница 226: ...209 System Section 6 4 2 Select the error method 3 Select End to leave this screen...
Страница 247: ...230 2 Dimensional Code Reader Section 8 1 8 1 2 Dimensional Code Reader V530 R150 Four 4 5 dia 165 min Unit mm...
Страница 263: ......
Страница 279: ......
Страница 281: ......
Страница 283: ......
Страница 289: ......