208
System
Section 6-4
6-4-6
Error Method
A V530-R150 does not perform reading while the BUSY terminal is
ON even when TRIG A is input. Set whether or not to turn ON the
ERR terminal if a trigger signal is sent while the BUSY terminal is ON
to inform the external device that the trigger has not been accepted.
1,2,3...
1.
Specify the ERR terminal operation.
Procedure
1,2,3...
1.
Select Error method.
ERR ON
(Default setting)
Reading is not performed while the BUSY terminal is
ON regardless of TRIG A input.
When TRIG A is input with the correct timing, the
ERR terminal turns OFF.
OFF
ERR terminal does not turn ON when TRIG A is
input while BUSY terminal is ON. Reading is not per-
formed.