Additional
information
Setting to adjust
(WebLink - Advanced
Settings Menu)
Description
Example Output
(For Read string
ABCDE.) The de-
limiter character
is a , <comma>.
Output Or-
der
Frame
Number
I/O
-
Output Object Info
Outputs the Frames num-
ber (number of images)
that were needed to get a
Good Read result. The
output is a 3 digit number.
ABCDE,F010
3
Code Posi-
tion Coordi-
nates
I/O
-
Output Object Info
Outputs the coordinates of
the four vertices of the
read symbol in pixels.
ABCDE,
(0032,0040)
(
0287,0056)
(0287,0279)
(0048,0271)
4
Print Quality
(ISO/IEC
16022)
Symbol Quality
-
ISO/IEC
16022 Parameters
Outputs the DataMatrix
Symbol Quality Grade de-
ABCDE,B,A,A,A
5
Print Quality
(Omron Mi-
croscan)
Symbol Quality
-
Omron
Microscan Parameters
Outputs the Omron Micro-
scan Proprietary Symbol
Quality Grade.
ABCDE,000,092,14
3,091,001,14.3,200
,16X16,PASS,349
6
Print Quality
(ISO/IEC
15415)
Symbol Quality
-
ISO/IEC
15415 Parameters
Outputs the Symbol Quali-
ty Grade defined by
ISO/IEC 15415 for 2D Co-
ABCDE,C,A,C,C,C,
A,A,A
7
Print Quality
(ISO/IEC
15416)
Symbol Quality
-
ISO/IEC
15416 Parameters
Outputs the Symbol Quali-
ty Grade defined by
ISO/IEC 15416 for Bar-
ABCDE,C,A,A,A,A,
A,C,A,A,A
8
Print Quality
(ISO/IEC
29158)
Symbol Quality
-
ISO/IEC
29158 Parameters
Outputs the Symbol Quali-
ty Grade defined by
ISO/IEC TR 29158 for 2D
Codes.
ABCDE,C,C,A,B,C,
A,A,A
9
Read Time
I/O
-
Read Duration
Output
Outputs the Read Duration
time in milliseconds.
ABCDE,100
10
Read Cycle
ID
I/O
-
Output Cycle ID
The Output Cycle ID num-
ber (number of Reads exe-
cuted) is output in hexa-
decimal format.
ABCDE,Cy-
cleID=0x8
11
*1.
For more information on Symbol Quality Grade, please refer to Autofocus Multicode Reader V430-F
Ser
ies User Manual (Z407) -
Symbol Quality Grade
.
Additional Information
When Multiple Symbol Reading is enabled, the Output Order is
read character string of symbol
1, additional information for symbol 1, read character string for symbol 2, additional information
for symbol 2, and so on
.
3-2-5
Controlling Operation from an External Device
The code reader can be controlled, have its settings viewed and changed from an external device with
the use of serial commands.
3 Controlling Operation and Data Output with Ethernet
3 - 37
V430-F Series Autofocus Multicode Reader User Manual for Communication Settings
3-2 Controlling Operation and Data Output with Serial
(TCP)
3
3-2-5
Controlling Operation from an External Device