ABCDE,(0867,0708)(0867,0708)(1741,0673)(1741,0673)
Output of the Symbol Quality Grade Information (ISO/IEC 15415)
• WebLink -
Setup
-
Gear Icon
-
Advanced Settings
-
Symbol Quality
-
ISO/IEC 15415
1
Enable the Symbol Quality Grade Standard to output
The following is an example where all ISO/IEC 15415 Symbol Quality Grade parameters are
enabled.
2
If necessary, change the Separator Character.
In WebLink -
Setup
-
Gear Icon
-
Advanced Settings
-
Symbol Quality
-
Global
, enter a
character for
Symbol Quality Separator
. Below is an example where
,
is used as the Separa-
tor Character.
3
The Symbol Quality Grade is output appended to the Read result.
The following example shows Symbol Quality Grades appended to the Read string
ABCDE
.
ABCDE,C,A,C,C,C,A,A,A
Additional
S
ymbol
I
nformation
T
hat
C
an
B
e Appended
Additional
information
Setting to adjust
(WebLink - Advanced
Settings Menu)
Description
Example Output
(For Read string
ABCDE.) The de-
limiter character
is a , <comma>.
Output Or-
der
Symbol
Identifier
I/O
-
Symbol Data Output
A (3 character) Symbol
Identifier indicating the
type of the read symbol is
put in front of its Read
string.
]dlABCDE
Put in front
of the Read
string
Decodes
per Trigger
I/O
-
Decodes per Trigger
Output
Outputs the number of
Good Read in Read Cycle
ABCDE,00002
1
Configura-
tion Data
Identifier
I/O
-
Database Identifier
Output
Outputs the Index Number
of the Configuration Data-
base used to get a Good
Read.
ABCDE,DB01
2
3 Controlling Operation and Data Output with Ethernet
3 - 36
V430-F Series Autofocus Multicode Reader User Manual for Communication Settings