This bit becomes
1
when the Trigger bit from the Output Assembly is received.
When the Trigger
bit is OFF, Trigger Acknowledged also becomes
0
.
・
Exposure Done
During exposure, this bit is set to
0
.
When Exposure is done, this bit becomes
1
.
・
Decoding
During image processing, this bit is set to
1
.
When image processing is done, this bit becomes
0
.
・
Data is Ready
When the data from Read Cycle Report and Data Cycle Report is confirmed, this bit becomes
1
.
When the next Read starts, this bit becomes
0
.
・
Read Cycle Pass
On Good Read, this bit becomes
1
.
When the next Read starts, this bit becomes
0
.
・
Read Cycle Fail
If the read cycle fails for any reason (No Read, Mismatch, etc,) this bit becomes 1. This bit will be
set to 0 at the start of a read cycle.
・
General Fault
When a
c
ode reader Error occurs, this bit becomes
1
. The user must resolve the problem by refer-
ing to the Fault Code field of the error code. After resolving the problem, the user must set "Reset
General fault" in the Output Assembly Control to
0
.
・
New
Matchcode
Acknowledged
This becomes
1
when the
V430-F
has accepted the Read string which was read by the next trigger
input as a new Master symbol.
When this bit becomes
1
,
the "Learn New
Matchcode
" bit in the Control field of the Output Assem-
bly must be set to
0
.
・
Matchcode
Enabled
When
Matchcode
is Enabled, this bit becomes
1
.
・
Image Sensor Calibrating
This bit is set to
1
while the device is executing the following calibrations.
Exposure
Gain
Focus (1.2 Megapixel and 5 Megapixel cameras)
This bit is set to
0
when
V430-F
calibration is complete.
・
Image Sensor Calibration Complete
This bit is set to
1
when the
V430-F
complete
s
executing the following calibrations.
Exposure
Gain
Focus (1.2 Megapixel and 5 Megapixel cameras)
・
Training
This bit is set to
1
while Training is in progress.
This bit is set to
0
when Training is complete.
・
Training Complete
This bit is set to
1
when Training is complete. If an error occurs, it is output by Fault Code area.
・
Optimizing
This bit is set to
1
while Optimization is in progress.
This bit is set to
0
when Optimization is complete.
・
Optimization Complete
This bit is set to
1
when Optimization processing is complete. If an error occurs, it is output by Fault
Code area.
Appendices
A - 10
V430-F Series Autofocus Multicode Reader User Manual for Communication Settings