1.
Trigger input
(TRIG signal)
2.
Output1
In Read Cycle
3.
Output2
No Read
OFF
ON
OFF
ON
OFF
ON
In Read Cycle
Turns ON if
No Read
*1
Read executed by Trigger Input.
*1 You can change the length of time the signal is ON. For further information, please refer to
2-1-8 Change the ON/OFF timing of the Output Signal (Output 1 to 3)
In Read Cycle
The assigned output signal turns ON when the code reader is In Read Cycle. The setting selected for
Output Mode
is disabled.
This signal turns ON when the Read Cycle starts. The timing for when it turns OFF depends on what is
set for the End of Read Cycle condition.
• When the End of Read Cycle condition is
Timeout
On Good Read: Turns OFF when there is a Good Read.
No Read
: Turns OFF when the Timeout period is exceeded.
• When the End of Read Cycle condition is
Last Frame
.
On Good Read: Turns OFF when there is a Good Read.
On
No Read
: It turns OFF when all the image capture executed by 1 trigger input is completed.
• When the End of Read Cycle condition is
New Trigger
.
On Good Read: Turns OFF when there is a Good Read.
On
No Read
: Turns OFF when a trigger is input and there is a New Read Cycle. At this time,
since
the New Read Cycle is in progress, it will turn ON again.
Below is an Output assignment example and Timing chart.
[Example assignment of OUTPUT signals]
• Output 1: In Read Cycle
For how to set up the Output signal assignments, please refer to
How to Assign the Output Signals
<Timing Chart>
• Trigger input
1. Trigger input
(TRIG signal)
2. Output1
In Read Cycle
OFF
ON
OFF
ON
In Read Cycle
Read executed by Trigger Input.
Trend Analysis
Monitors the frequency of Mismatches and No Reads as well as the Number of Reads per Trigger, and
turns ON when a certain threshold is met.
This can be used to monitor quality indicators like the percentage of Matches and Read Rate.
2 Controlling Operation and Data Output with Parallel
2 - 13
V430-F Series Autofocus Multicode Reader User Manual for Communication Settings
2-1 Controlling Operation and Data Output
with Parallel
2
2-1-7
Change the Assignments for the Output Signal (Output 1 to 3) ON Condition