Member Description
•
INFO BITS
MXL/SLC Input Assembly (Instance ID: 102)
on page A - 8 - Same structure as
•
Configuration Change Detection
MXL/SLC Input Assembly (Instance ID: 102)
•
Device Status
MXL/SLC Input Assembly (Instance ID: 102)
on page A - 8 - Same structure as
•
Error Code
MXL/SLC Input Assembly (Instance ID: 102)
on page A - 8 - Same structure as
•
Counters
MXL/SLC Input Assembly (Instance ID: 102)
on page A - 8 - Same structure as
•
Read Cycle
Report
MXL/SLC Input Assembly (Instance ID: 102)
on page A - 8 - Same structure as
•
Decode Cycle Report
MXL/SLC Input Assembly (Instance ID: 102)
on page A - 8 - Same structure as
•
Decode
Data
Length
Stores the number of characters in the Read string.
•
Decode Data
String
Stores the Read string. When additional information such as Print Quality Grading Standard is set, it
is stored following the Read string.
Assembly Memory Allocation
Member Name
Data Type
Bit Number
Data Length
Byte Offset
32 bit
InfoBits
SINT
1 Byte
0
Bit Run Mode
0
1 bit
Bit Connection Faulted
1
1 bit
Reserved
2
1 bit
Reserved
3 - 7
5 bit
Reserved
SINT
1 Byte
1
Configuration Change
Detect
ion
SINT
1 Byte
2
Config Change Detect
0
1 bit
Reserved
1 - 7
7 bit
Reserved
‐
1 byte
3
Appendices
A - 16
V430-F Series Autofocus Multicode Reader User Manual for Communication Settings